MoltenVoltage Master Control MV-58 Скачать руководство пользователя страница 4

Molten Voltage™

Master Control MV-58

Owner’s Manual - p.4

[email protected]

© 2015 - MoltenVoltage.com - All Rights Reserved.

v 1.09

Tempo change times out after 2.5 seconds.  If a single tap was received, then the display again

shows the currently selected Program number.

If multiple taps were received, then “tPo” “SEt” (Tempo Set) will be displayed to indicate that a

new tempo has been received.  The Display will then show the currently selected Program number.

Note: This new tempo is only temporary and will not be saved unless the Program is saved.

Tempo can be continually adjusted 

on-the-fly 

with the TAP TEMPO Button, whether or not MIDI

Clock is being sent.

Tempo changes affect only the current Program and are not stored unless the SAVE function is

used.

Similarly, Tempo changes do not affect any pending Program (indicated by a flashing Program

number).  However, if the pending Program uses the "oLd" tempo, it will use the existing tempo.

Program Storage

Master Control stores the tempo associated with each of the 128 programs.

Holding down the first press of the TAP Button for more than 2.5 seconds causes Master Control to

save the current tempo at the selected Program location.  Once the TAP Button has been held long
enough, the Display shows the letter “P”.  Release the button to store the program.

At the time the tempo is stored, Master Control simultaneously sends a command to all

compatible Molten Voltage devices connected to the MIDI OUT, causing them to self-program
and store their settings for the selected Program.

The selected Program is the one that is shown by the Display.  If the Program number is flashing,

the selected Program is not the same as the one that is currently running.

As such,

 the current Program can be copied into a new Program location

 by selecting a

different program number but not engaging that Program (normally done by pressing the START Button).
Instead, hold down the TAP Button until the letter “P” appears.  The current settings will be saved to the
selected Program when the button is released.

If the DOWN Button is pressed while the TAP Button is being held (and after the letter “P”

appears), the decimal point after the “P” will turn on.  This indicates that Master Control will not save the
current tempo, but instead will set the tempo status to "oLd", meaning 

that

 Program will use the then-

current tempo when it is recalled.

Following a SAVE, the saved Program becomes the current Program and Program Change data is

sent.

Note: If you tap in a new tempo, you need to wait until you are done tapping and Tap Mode ends

(about 2.5 seconds after the last tap) before you can store the new tempo.

Note: MIDI Clock output will stop while Molten Voltage self-program data is sent.  As such, it will

usually be necessary to restart drum machines, sequencers, etc. after storing a tempo.

Содержание Master Control MV-58

Страница 1: ...functional stand alone Master Controller for MIDI controlled PedalBoards Rock Solid MIDI Clock Generator Call up presets on your MIDI enabled effects Solid Professional Grade construction including R...

Страница 2: ...ke switching and storing programs as simple as possible so the end user can concentrate on being creative Programs are selected using the UP and DOWN buttons or by turning the SELECT Knob The selected...

Страница 3: ...vious Program is recalled the previous Program will recall its stored tempo rather than the altered tempo In order to keep an altered tempo the Program must be saved as described below Note No program...

Страница 4: ...m At the time the tempo is stored Master Control simultaneously sends a command to all compatible Molten Voltage devices connected to the MIDI OUT causing them to self program and store their settings...

Страница 5: ...increase the Program numbers If the TAP Button has been pressed and released pressing the UP Button will increase the tempo by one bpm Pressing and holding the UP Button will quickly increase the tem...

Страница 6: ...mber has been selected as described above TEMPO LED G The TEMPO LED always flashes in time with the current tempo at quarter note intervals The tempo corresponds to the standard quarter note interval...

Страница 7: ...use the oLd tempo from the previous Program rather than the current tempo MIDI Compatibility The primary MIDI channel for the Molten Voltage system is MIDI Channel 15 All MIDI Program Change messages...

Страница 8: ...d or Act Switch modes by pressing the Up button Lock in your selection by pressing the Down button Switch between the two modes during runtime by pressing both the Up and Down buttons at the same time...

Страница 9: ...Many more available soon MIDI IMPLEMENTATION CHART Function Generated Comment Note On X Note Off X Aftertouch X Control Change X Program Change O On selected MIDI Channel Channel Pressure X Pitch Ben...

Страница 10: ...IDI device is configured to receive MIDI Clock Consult the User s Guide for that device MIDI device is not receiving MIDI Program Change messages Set your MIDI device to receive MIDI Program Change me...

Страница 11: ...on contained in this publication regarding device applications and the like is provided only for your convenience and may be superseded by updates It is your responsibility to ensure that your applica...

Отзывы: