![Molnar MF1705-93-OH-3T Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/molnar/mf1705-93-oh-3t/mf1705-93-oh-3t_maintenance-manual_1824299014.webp)
Molnar Hoists
All Rounder
Servicing
14
Electrical, controls & travel limits
Electrical, controls & travel limits
1
Check the operation of limit switches:
raise hoist to
ensure that limit switches stop the hoist operating
beyond the limits of travel.
2
Visually inspect electrical components for damage.
>
Overhead limit switch sensor bar:
ensure it is
mounted securely to its mounting point, and moves
freely. Lubricate slide pins.
>
Electrical conduit
: ensure it is not worn,
cracked or disconnected at either end.
>
Side limit switch:
ensure it is mounted securely to its
mounting point, and moves freely.
>
Junction boxes:
check both boxes are mounted
securely.
>
Control button box:
check the box is mounted securely
to its mounting bracket. Check that the cover is fitted
securely and that the button moves freely.
3
Check LOWERING handle pivot is operating freely. Ensure
it does not hold the valve open. Lubricate with spray
lubricant.
4
Ensure the LOWERING handle is not bent and is secured
with split pin (at the pivot).
overhead
limit switch
sensor bar
overhead limit switch
side limit switch
conduit
junction
junction
lowering
handle
pivot
control button box
conduit