background image

Distributor of Molex Connector Corporation: Excellent Integrated System Limited

Datasheet of 0638276900 - HAND CRIMP TOOL 
Contact us: [email protected] Website: www.integrated-circuit.com

Hand Crimp Tool for 1.25mm (.049") Pitch Wire-to-Board Crimp Terminals 

Doc No: ATS-6382769HM 

Release Date: 12-16-14 

UNCONTROLLED COPY

 

Page 3 of 6 

Revision: A 

Revision Date: 12-16-14 

WIRE 

PUNCH 

TERMINAL 

WIRE STOP 

BLADE 

Figure 2 

Figure 3 

WIRE 

TERMINAL 

LOCATOR 

INSULATION 

PUNCH 

INSULATION 

ANVIL 

WIRE STOP 

BLADE 

CONDUCTOR 

ANVIL 

CONDUCTOR 

PUNCH 

 

OPERATION 

 

Open the tool by squeezing the handles together, at the end of 
the closing stroke, the ratchet mechanism will release the 
handles, and the hand tool will spring open. 
 

1.

 

With the hand tool in the open position, pivot the terminal 
locator open by pulling up on the locator knob and lift the 
wire stop blade up.  See Figure 1. 

2.

 

Insert the terminal into the correct profile until the terminal 

is fully seated and stops.  Make sure the wire stop blade is 
fully seated on the terminal behind the conductor grip 
section. 

3.

 

Gently pivot the locator closed. 

4.

 

Bring down the wire stop blade. 

 
 
 

 
 
 
 

 
 
 
 

 
 
5.

 

Slide the pre-stripped wire into the terminal; make sure to aim the wire brush towards the tip point on the 
wire stop blade.  See Figure 2.  Align the wire so that it is parallel and sitting into the terminal.  Maintain a 

light and constant pressure on the wire that is seated in the terminal at all times.  (Do not let go of the 
wire.)  Be sure to hold the wire and terminal in place until the terminal is fully crimped.  See Figure 3. 

6.

 

Close the tool until the ratchet releases. 

7.

 

Lift the wire stop blade up. 

8.

 

Carefully remove the crimped terminal. 

 

Note:

  To maintain good brush control and a consistent bell mouth the crimping instructions must be followed. 

 

Note:

 The tamper proof ratchet action will not release the tool until it has been fully closed. 

 

Terminal Locator Replacement/Change Over 

This section describes the procedure for changing locators.  
 

Removal

 

1.

 

With the tool in the open position, pivot the terminal locator outward. 

2.

 

Remove the M4 BHCS.  See Figure 4. 

TERMINAL 

SEATED IN 

LOCATOR 

SWING 

LOCATOR 

OPEN 

Figure 1 

HAND TOOL 

OPEN 

WIRE 

STOP 

BLADE 

                               4 / 7

                               4 / 7

Содержание 63827-6900

Страница 1: ...ent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Molex Connector Corporation Molex Connector Corporation 0638276900 0638276900 For any questions you can email us directly For any questions you can email us directly sales integrated cir...

Страница 2: ...ensures complete crimps Ergonomically designed soft handles Precisely designed crimping profiles with simple contact positioning Easy handling due to outstanding force ratio Modular Crimp Head is removable and can be use in the Air Powered Tool Order No 63816 0100 accompanied by Air Powered Crimp Adapter Order No 63816 0700 Can also be used in the Battery Powered Tool Order No 63816 0200 110 V or ...

Страница 3: ...88 034 1 09 043 0 90 035 4 9 1 10 X Tool Qualification Notes 1 Pull Force should be measured with no influence from the insulation crimp 2 The above specifications are guidelines to an optimum crimp Notes 1 This tool should only be used for the terminals and wire gauges specified on this sheet 2 This tool is not adjustable for crimp height however crimp force is adjustable See instructions above V...

Страница 4: ...de is fully seated on the terminal behind the conductor grip section 3 Gently pivot the locator closed 4 Bring down the wire stop blade 5 Slide the pre stripped wire into the terminal make sure to aim the wire brush towards the tip point on the wire stop blade See Figure 2 Align the wire so that it is parallel and sitting into the terminal Maintain a light and constant pressure on the wire that is...

Страница 5: ...ivot points and bearing surfaces are protected with a thin coat of high quality machine oil Do not oil excessively The tool was engineered for durability but like any other equipment it needs cleaning and lubrication for a maximum service life of trouble free crimping Light oil such as 30 weight automotive oil used at the oil points every 5 000 crimps or 3 months will significantly enhance the too...

Страница 6: ...e service install or adjust this Modular Crimp Head without proper instruction and without first reading and understanding the instructions in the proper Manual or Specification Sheet See Chart below for the correct Manual or Specification Sheet WARNING NEVER install tooling or service this tool while it is into any power source Disconnect the power by unplugging or turn off the Actuator from its ...

Страница 7: ...14 UNCONTROLLED COPY Page 6 of 6 Revision A Revision Date 12 16 14 RATCHET RELEASE LEVER HANDLE SPRING CRIMPING SPRING 2 LOCATOR 2 1 4 Figure 9 M4 X 8mm LONG BHCS 3 5 6 PARTS LIST Item Order Number Description Quantity 1 63827 6970 Modular Crimp Head 1 2 63816 0000 Hand Crimp Frame Short 1 3 63827 6975 Locator 1 4 63816 0001 Locking Pin 2 5 63600 0525 Handle Spring 1 6 63600 0520 Crimping Spring 2...

Отзывы: