![Moffat BLUE EVOLUTION G91 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/moffat/blue-evolution-g91/blue-evolution-g91_service-manual_1822820038.webp)
B
Appendix B: Gas Conversion
36
Blue Seal Evolution Series Gas Salamander
© Copyright Moffat Ltd. 9 February 2016
Amendment 9
Gas Regulator (Up to Serial No.401964)
1.
Ensure that the gas supply is turned off.
2.
Unscrew the slotted cap from the regulator.
3.
Unscrew the spring adjusting nut and remove the spring.
4.
Fit the correct colour spring for the gas type being used and
screw in the spring adjusting nut.
5.
Turn on the gas supply and the appliance.
6.
Adjust the spring adjusting nut to achieve the correct operating
pressure.
NOTE: The operating pressure to be measured at the manifold
test point and with all burners operating at the “High
Flame” setting.
7.
Verify the operating pressure remains correct (Re-adjust the
regulator if required).
8.
Screw the cap back into the regulator.
Commissioning
Before leaving the converted installation;
1.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
2.
Check the following functions in accordance with the operating instructions specified in the 'Operation' section of the User
manual.
Light the Pilot Burners.
Light the Main Burners.
Check the Low Fire burner operation.
Check the High Fire burner operation.
Ensure all controls operate correctly.
NOTE: If for some reason it is not possible to get the unit to operate correctly, shut off the gas supply and contact the
supplier of this unit.
Spring Adjusting
Nut
Cap Nut
Regulator Spring
Coloured for gas type;
-
Orange
- Nat
Gas
Fig B4
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning
Содержание BLUE EVOLUTION G91
Страница 4: ...Blue Seal Evolution Series Gas Salamander Copyright Moffat Ltd 9 February 2016 Amendment 9...
Страница 46: ......