![Moffat BLUE EVOLUTION G91 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/moffat/blue-evolution-g91/blue-evolution-g91_service-manual_1822820037.webp)
B
Appendix B: Gas Conversion
35
Blue Seal Evolution Series Gas Salamander
© Copyright Moffat Ltd. 9 February 2016
Amendment 9
Gas Conversion Procedure (up to Ser No. 401964)
NOTE:
These conversions should only be carried out by qualified persons. All connections must be checked for
leaks before re-commissioning the appliance.
For all the following conversion instructions, the side panels have to be removed (Remove the two screws
at the bottom of each side panel).
All conversion details apply to both L/Hand and R/Hand burners.
For all relevant gas specifications refer to the table at the end of this section.
Main Burner Injectors
1.
Unscrew the main burner injectors (
1
/
2
” A/F).
2.
Determine the correct injector sizes for the corresponding gas type from the
rating plate affixed to the right hand side panel front bottom corner.
3.
Replace with the correct size injectors.
Pilot Injectors
1.
Unscrew the cap from the rear of the pilot burners, and unscrew the pilot
injectors (taking care not to lose the springs).
2.
Determine the correct pilot injector sizes for the corresponding gas from the
rating plate affixed to the right hand side panel front bottom corner.
3.
Replace with the correct size pilot injectors.
NOTE:
Ensure that the Pilot Injectors are fully screwed in.
Low Fire Adjustment
NOTE:
If the salamander is fitted with the Adjustable Racking System, this has to be removed to enable the 2 front control
panels to be removed. Refer to the ‘Installation and Operation’ Manual, “Cleaning” Section for information on how
to remove and refit the Adjustable Racking System.
1.
Remove the following:-
Gas control knobs from front of unit.
Two front control panels.
2.
Light main burners and check flame size on
Low
position.
Adjust burner gas control valve low fire adjustment screw as shown in ‘Gas
Specifications’ tables at rear of this section.
NOTE:
‘Low Fire Screw’ should be sealed with coloured paint on completion of
low fire adjustment.
3. Refit
the
following:-
Two side access panels.
Two front control panels.
Gas control knobs.
Main Burner
Injector
Pilot Injector Cap
Figure B.1
Figure B.2
Ensure Appliance is isolated from gas supply before commencing servicing.
Caution
Low Fire
Adjustment
Figure B.3
Содержание BLUE EVOLUTION G91
Страница 4: ...Blue Seal Evolution Series Gas Salamander Copyright Moffat Ltd 9 February 2016 Amendment 9...
Страница 46: ......