background image

              

 
 

SEAL PROBE (WATER-IN-OIL SENSOR)   

 
PUMP CAN ALSO BE EQUIPPED WITH A WATER-IN-OIL SENSOR FITTED IN THE CONTACTOR 
CHAMBER. A CONDUCTIVITY PROBE IS FITTED IN THE SEAL CHAMBER & MONITORS THE 
CONDITION OF THE OIL. IN THE EVENT OF A CONTAMINATION OF THE LUBRICATING OIL BY 
PUMPED WATER THE PROBE SENDS A SIGNAL TO THE BUILT IN SENSOR WHICH CUTS OFF 
POWER TO THE MOTOR. THIS INDICATES A SEAL FAILURE OR WORN OUT SEAL AND IT IS 
NECESSARY TO REPLACE THE SEALS AND FILL IN NEW OIL. 
 
THE CONDUCTIVITY PROBE IS CONNECTED TO A 24V AC SUPPLY THROUGH A TRANSFORMER. 
IN THE EVENT OF A SEAL FAILURE AND CONTAMINATION OF OIL BY WATER (APPROX. 10%) 
THE PROBE GENERATES A SIGNAL, DETECTED BY A SENSOR, WHICH OPERATES A RELAY 
THROUGH THE BRIDGE RECTIFIER. THIS RELAY OPERATES THE CO CONTACT WHICH OPENS 
THE COIL CIRCUIT OF THE MAIN CONTACTOR AND ISOLATES THE PUMP FROM THE POWER 
SUPPLY.  
 
THE SENSOR COMPLETE WITH TRANSFORMER IS HOUSED IN A SHEET STEEL ENCLOSURE DULY 
WIRED. THE ENCL. INCORPORATES AN LED AND A REMOVABLE FUSE. IN THE EVENT OF 
WATER CONTAMINATION IN THE OIL THE SENSOR WILL ISOLATE THE PUMP AND THE LED 
WILL LIGHT UP INDICATING THE OPERATION OF THE SENSOR. THE PUMP WILL NOT START 
IN THIS CONDITION. IF YOU WOULD LIKE TO OPERATE THE PUMP, REMOVE THE FUSE AND 
START THE PUMP. 
 
WARNING: THE UNIT SHOULD NOT BE OPERATED FOR MORE THAN 10 DAYS AFTER THE SENSOR 
HAS TRIPPED THE PUMP. THE PROBE OPERATION IS AN EARLY WARNING SIGNAL THAT THE 
SEALS NEED REPLACEMENT --- DO NOT IGNORE THE SAME. IT IS ESSENTIAL THAT THE 
SEALS BE REPLACED AND NEW OIL FILLED AS SOON AS POSSIBLE TO PREVENT FURTHER 
DAMAGE TO THE UNIT. THE FUSE SHOULD BE REMOVED AND THE PUMP OPERATED IF 
ABSOLUTELY NECESSARY. 
 
IN THE EVENT OF OVERHEATING OF THE STATOR WINDING FOR ANY REASON, THE EMBEDDED 
THERMAL SWITCHES WILL OPEN, CAUSING THE STARTER COIL TO DROP OUT AND ISOLATE 
THE PUMP UNIT FROM THE MAINS. THESE SWITCHES DO NOT PROVIDE ANY PROTECTION IN 
THE CASE OF A SHORT CIRCUIT, AND ADEQUATE H.R.C. FUSES SHOULD BE USED FOR SHORT 
CIRCUIT PROTECTION. 
 
 
 

GENERAL OVERHAUL AND OIL CHECK. (ALL MODELS)

 

 

DIS-ASSEMBLY (REFER DRG.NO.NC/200/01 SHEET 1 & 2)AT END OF MANUAL

 

 
1. ALWAYS REPLACE O-RINGS WITH NEW ONES WHENEVER DISMANTLING AND RE-ASSEMBLING 
A PUMP. NEVER RE-USE OLD O-RINGS. 
 
2. ALWAYS ISOLATE THE UNIT BEFORE REMOVING THE CONTACTOR COVER (1).BE CAREFUL 
WITH O-RINGS (8) AND SEALING SURFACES. PROTECT THE CONTACTOR CHAMBER AGAINST 
RAIN AND MOISTURE. CLEAN THE SEALING SURFACES CAREFULLY AND GREASE THE NEW 
O-RINGS BEFORE FITTING THE SAME. DO NOT USE THE OLD O-RINGS.  
 
3. DISCONNECT STATOR LEADS AND CHECK COIL OF CONTACTOR AND CONDITION OF 
CONTACTS. IF CONTACTS ARE CORRODED OR PITTED, REPLACE CONTACTOR OR A NEW SET OF 
CONTACTS. SNIP OFF LEAD WIRE CONNECTORS AND UNSCREW GROMMET NUT (48). REMOVE 
LEAD WASHER (49) AND LEAD GROMMET (47). SLACKEN MOTOR LEAD WIRES TO FACILITATE 
REMOVAL OF STATOR LATER, IF NECESSARY. 
 
4. LOOSEN NUT (5) AND REMOVE OUTLET (24/27). 
 
5. LOOSEN NUTS (5)(4 NOS TIGHTENING VOLUTE AGAINST PUMP BASE) AND REMOVE 
VOLUTE. THE VOLUTE HAS TO BE MANEUVERED AND SLIDES OUT FROM ONE OPENING IN THE 
PUMP BASE (23). 
 
6. THE IMPELLER (33/34/35/93/94/95) IS NOW IN VIEW. 

Содержание NC 06360-M

Страница 1: ...ERATING INSTRUCTIONS INSTALLATION MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST Mody Pumps Inc 2166 Zeus Court Bakersfield CA 93308 Tel 661 392 7600 FAX 661 392 7601 E Mail sales modypump com http www...

Страница 2: ...e pump in its operating position so it does not tip over fall or slide 14 Keep away from impeller when power is connected 15 Submersible Pumps are not approved for use in swimming pools recreational w...

Страница 3: ...FROM THE PUMP TECHNICAL DESCRIPTION THE PUMPSET IS IN A MODULAR CONSTRUCTION ENSURING EASY AND SIMPLE SERVICEABILITY THE MAJOR DESIGN FEATURES ARE AS UNDER A THERMAL PROTECTION SEE UNDER MOTOR PROTEC...

Страница 4: ...CY INSTALLATION CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP CHECK THAT FUSES ARE INTACT USE SHORTEST POSSIBLE HOSE IN RECOMMENDED DIMENSION AVOID SHARP BENDS CREASES AND CONTRACTIONS...

Страница 5: ...CONN 2 PUMP WORN DOWN 2 REPLACE IMPELLER PUMP OUTPUT LOW3 LONG HOSE AND DIAMETER 3 CHECK PRESSURE LOSSES TOO SMALL 4 PRESSURE HEAD TOO HIGH 4 INSTALL BIGGER PUMP 5 LEAKING CRACKED OUTLET 5 REPLACE OUT...

Страница 6: ...THE COIL CIRCUIT IS CONNECTED BETWEEN TWO OF THE INCOMING PHASE WIRES WHEN THE PUMP IS CONNECTED TO THE POWER MAINS THE COIL GETS VOLTAGE AND ATTRACTS THE CONTACT BRIDGE THE MOTOR STARTS AND THE PUMP...

Страница 7: ...DO NOT IGNORE THE SAME IT IS ESSENTIAL THAT THE SEALS BE REPLACED AND NEW OIL FILLED AS SOON AS POSSIBLE TO PREVENT FURTHER DAMAGE TO THE UNIT THE FUSE SHOULD BE REMOVED AND THE PUMP OPERATED IF ABSOL...

Страница 8: ...HOLD THE LOWER BEARING BRACKET AGAINST THE STATOR CASING BY MEANS OF TWO SCREW DRIVERS REMOVE THE LOWER BRACKET FROM THE STATOR CASING THE COMPLETE ROTOR 14 15 16 WITH BEARINGS 80 BEARING COVER 20 AN...

Страница 9: ...DESCRIPTION PART NO QUANTITY 1 MECHANICAL SEAL 535 022 00 1 NO 2 MECHANICAL SEAL 535 022 00 1 NO 3 O RING SET 375 004 66 2 SETS 4 CABLE GROMMET 260 017 66 2 NOS 5 LEAD GROMMET 260 031 66 2 NOS 6 UPPE...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...rrected for field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccurac...