background image

              

 
 

OIL SPECIFICATIONS

 

 
A) H.P. ENKLO OIL 46/48 
B) SHELL TELLUS 29. 
C) CHEVRON UNIVOLT 60/N61 
 

USE NON-CONDUCTIVE, NON-FOAMING OIL ONLY 
PLEASE NOTE THE SEAL CHAMBER CONTAINS APPROX. 1.6 LITRES OF OIL

 
 
 

RECOMMENDED SPARES FOR TWO YEARS OPERATION (NC SERIES) 

 

S. NO.  DESCRIPTION                 PART NO.                QUANTITY 

1.      MECHANICAL SEAL      535-022-00        1 NO. 

2.      MECHANICAL SEAL      535-022-00        1 NO. 

3.      "O" RING SET         375-004-66        2 SETS. 

4.      CABLE GROMMET        260-017-66        2 NOS. 

5.      LEAD GROMMET         260-031-66        2 NOS. 

6.      UPPER BEARING        020-005-07        1 NO. 

7.      LOWER BEARING        020-014-07        1 NO. 

8.      IMPELLER(NC10360M)   300-051-22        1 NO. 

9.      WEAR PLATE           715-005-80        1 NO. 

10.     CONTACTOR(NC10360M)  100-009-00        1 NO. 

11.     LOCK WASHER          695-004-21        1 NO. 

 
 
* PLEASE SPECIFY IMPELLER # PER PUMP MODEL and Frequency 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание NC 06360-M

Страница 1: ...ERATING INSTRUCTIONS INSTALLATION MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST Mody Pumps Inc 2166 Zeus Court Bakersfield CA 93308 Tel 661 392 7600 FAX 661 392 7601 E Mail sales modypump com http www...

Страница 2: ...e pump in its operating position so it does not tip over fall or slide 14 Keep away from impeller when power is connected 15 Submersible Pumps are not approved for use in swimming pools recreational w...

Страница 3: ...FROM THE PUMP TECHNICAL DESCRIPTION THE PUMPSET IS IN A MODULAR CONSTRUCTION ENSURING EASY AND SIMPLE SERVICEABILITY THE MAJOR DESIGN FEATURES ARE AS UNDER A THERMAL PROTECTION SEE UNDER MOTOR PROTEC...

Страница 4: ...CY INSTALLATION CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP CHECK THAT FUSES ARE INTACT USE SHORTEST POSSIBLE HOSE IN RECOMMENDED DIMENSION AVOID SHARP BENDS CREASES AND CONTRACTIONS...

Страница 5: ...CONN 2 PUMP WORN DOWN 2 REPLACE IMPELLER PUMP OUTPUT LOW3 LONG HOSE AND DIAMETER 3 CHECK PRESSURE LOSSES TOO SMALL 4 PRESSURE HEAD TOO HIGH 4 INSTALL BIGGER PUMP 5 LEAKING CRACKED OUTLET 5 REPLACE OUT...

Страница 6: ...THE COIL CIRCUIT IS CONNECTED BETWEEN TWO OF THE INCOMING PHASE WIRES WHEN THE PUMP IS CONNECTED TO THE POWER MAINS THE COIL GETS VOLTAGE AND ATTRACTS THE CONTACT BRIDGE THE MOTOR STARTS AND THE PUMP...

Страница 7: ...DO NOT IGNORE THE SAME IT IS ESSENTIAL THAT THE SEALS BE REPLACED AND NEW OIL FILLED AS SOON AS POSSIBLE TO PREVENT FURTHER DAMAGE TO THE UNIT THE FUSE SHOULD BE REMOVED AND THE PUMP OPERATED IF ABSOL...

Страница 8: ...HOLD THE LOWER BEARING BRACKET AGAINST THE STATOR CASING BY MEANS OF TWO SCREW DRIVERS REMOVE THE LOWER BRACKET FROM THE STATOR CASING THE COMPLETE ROTOR 14 15 16 WITH BEARINGS 80 BEARING COVER 20 AN...

Страница 9: ...DESCRIPTION PART NO QUANTITY 1 MECHANICAL SEAL 535 022 00 1 NO 2 MECHANICAL SEAL 535 022 00 1 NO 3 O RING SET 375 004 66 2 SETS 4 CABLE GROMMET 260 017 66 2 NOS 5 LEAD GROMMET 260 031 66 2 NOS 6 UPPE...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...rrected for field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccurac...