F] CABLE GLAND ASSEMBLY

: THE PUMP IS SUPPLIED WITH 50 FEET CABLE AS STANDARD. 

THE CABLE IS A 4 CORE EPR SHEATHED AND INSULATED CONFORMING TO INT'L STD. THE 
CABLE IS WATERPROOF AND CAN BE COMPLETELY SUBMERGED IN WATER. THE CABLE IS 
TERMINATED IN THE PUMP AT THE CABLE GLAND. THE GLAND ASSEMBLY SEALS THE CABLE 
ON THE OUTSIDE SHEATH. A WATER DAM ARRANGEMENT IS ALSO PROVIDED WHICH SEALS THE 
INDIVIDUAL CORES OF THE CABLE. THIS FEATURE IS UNIQUE AND IS ESSENTIAL TO 
PREVENT WATER SEEPING THROUGH THE CORES OF THE CABLE INTO THE TERMINAL CHAMBER 
IN THE EVENT OF A CUT CABLE. THE CABLE IS ALSO SHEATHED FOR THE FIRST ONE METER 
BY MEANS OF A CABLE GRIP MADE OF STAINLESS STEEL. THIS IS ESSENTIAL TO ENSURE 
THAT THERE IS NO UNDUE STRAIN ON THE CABLE IF THE PUMP IS PULLED OR LOWERED 
INADVERTENTLY BY MEANS OF THE CABLE. COMPLETE DETAILS OF THE CABLE GLAND 
ASSEMBLY ARE SHOWN IN THE DRAWING. 
 

G] ELECTRICAL INFORMATION

: MOTORS ARE TYPICALLY DESIGNED TO OPERATE ON 

230/460V AT 60 HZ, 415V AT 50 HZ. EXPORT DESTINED PUMPS ARE PREWIRED FOR SINGLE 
VOLTAGE AND FREQUENCY. MAXIMUM DEVIATION IN VOLTAGE ALLOWED IS -/+ 6% AND 
FREQUENCY -/+ 3%. CHECK NAME PLATE FOR OPERATING VOLTAGE AND FREQUENCY.  
 
 

INSTALLATION

 

 

CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP. 

 

CHECK THAT FUSES ARE INTACT. 

 

USE SHORTEST POSSIBLE HOSE IN RECOMMENDED DIMENSION. AVOID SHARP BENDS, 
CREASES, AND CONTRACTIONS. 

 

THE MAXIMUM SUBMERGENCE RECOMMENDED IS 50 FEET. 

 

THE SPECIFIC GRAVITY OF THE PUMPED FLUID SHOULD NOT EXCEED 1.1. 

 

NEVER LIFT OR PULL THE PUMP BY MEANS OF THE CABLE. SUSPEND THE PUMP BY A 
ROPE OR PREFERABLY PLACE IT ON A SOLID BASE. 

 

WIRE THE PUMP TO THE MAINS CORRECTLY. ALWAYS USE A STARTER OR A PANEL BOARD. 
SEE INSTRUCTIONS UNDER "MOTOR PROTECTION" BELOW. 

 

AT THE STARTING MOMENT, THE PUMP SHALL MAKE A KICK, WHICH IS OPPOSITE TO THE 
DIRECTION OF ROTATION OF THE IMPELLER. SHIFT TWO PHASES IN THE POWER 
CONNECTION IF THE KICK IS IN THE WRONG DIRECTION. THE CORRECT DIRECTION IS 
INDICATED ON THE PUMP COVER AT THE TOP OF THE PUMP. 

 

CHECK LEVEL AND CONDITION OF THE OIL AT SERVICE EVERY SIX MONTHS. IF THE OIL 
IS EMULSIFIED BY WATER THE SEALS MUST BE REPLACED. 

 

THE SHAFT SEAL SHOULD BE CHECKED FOR WEAR EVERY 2500 HRS. OF OPERATION. IF 
SEAL FACES SHOW ANY SIGNS OF WEAR, THEY SHOULD BE REPLACED. REFER TO PAGE 5 
FOR SERVICING THE PUMP SEALS. 

 
 
HRC FUSE RECOMMENDED

 

 

MAINS VOLTAGE AT SITE               NC06 M      NC08 M            NC10 M  

220 VOLTS  3 PHASE               25 AMPS    30 AMPS     40 AMPS 

380 VOLTS  3 PHASE               16 AMPS    20 AMPS     25 AMPS 

415 VOLTS  3 PHASE               16 AMPS    16 AMPS     25 AMPS 

460 VOLTS  3 PHASE               16 AMPS    16 AMPS     25 AMPS 

 
 
 
 
 
 
 
 

 

Содержание NC 06360-M

Страница 1: ...ERATING INSTRUCTIONS INSTALLATION MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST Mody Pumps Inc 2166 Zeus Court Bakersfield CA 93308 Tel 661 392 7600 FAX 661 392 7601 E Mail sales modypump com http www...

Страница 2: ...e pump in its operating position so it does not tip over fall or slide 14 Keep away from impeller when power is connected 15 Submersible Pumps are not approved for use in swimming pools recreational w...

Страница 3: ...FROM THE PUMP TECHNICAL DESCRIPTION THE PUMPSET IS IN A MODULAR CONSTRUCTION ENSURING EASY AND SIMPLE SERVICEABILITY THE MAJOR DESIGN FEATURES ARE AS UNDER A THERMAL PROTECTION SEE UNDER MOTOR PROTEC...

Страница 4: ...CY INSTALLATION CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP CHECK THAT FUSES ARE INTACT USE SHORTEST POSSIBLE HOSE IN RECOMMENDED DIMENSION AVOID SHARP BENDS CREASES AND CONTRACTIONS...

Страница 5: ...CONN 2 PUMP WORN DOWN 2 REPLACE IMPELLER PUMP OUTPUT LOW3 LONG HOSE AND DIAMETER 3 CHECK PRESSURE LOSSES TOO SMALL 4 PRESSURE HEAD TOO HIGH 4 INSTALL BIGGER PUMP 5 LEAKING CRACKED OUTLET 5 REPLACE OUT...

Страница 6: ...THE COIL CIRCUIT IS CONNECTED BETWEEN TWO OF THE INCOMING PHASE WIRES WHEN THE PUMP IS CONNECTED TO THE POWER MAINS THE COIL GETS VOLTAGE AND ATTRACTS THE CONTACT BRIDGE THE MOTOR STARTS AND THE PUMP...

Страница 7: ...DO NOT IGNORE THE SAME IT IS ESSENTIAL THAT THE SEALS BE REPLACED AND NEW OIL FILLED AS SOON AS POSSIBLE TO PREVENT FURTHER DAMAGE TO THE UNIT THE FUSE SHOULD BE REMOVED AND THE PUMP OPERATED IF ABSOL...

Страница 8: ...HOLD THE LOWER BEARING BRACKET AGAINST THE STATOR CASING BY MEANS OF TWO SCREW DRIVERS REMOVE THE LOWER BRACKET FROM THE STATOR CASING THE COMPLETE ROTOR 14 15 16 WITH BEARINGS 80 BEARING COVER 20 AN...

Страница 9: ...DESCRIPTION PART NO QUANTITY 1 MECHANICAL SEAL 535 022 00 1 NO 2 MECHANICAL SEAL 535 022 00 1 NO 3 O RING SET 375 004 66 2 SETS 4 CABLE GROMMET 260 017 66 2 NOS 5 LEAD GROMMET 260 031 66 2 NOS 6 UPPE...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...rrected for field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccurac...

Отзывы: