28
wear protective gloves and goggles
do not block charging flaps and ash pan doors
perform grate readjustment using the ash pan lever
use portable 24V lamps
maintain order and cleanness in the boiler room
maintain good technical condition of the boiler and its related
installation
during the winter season ensure that the heating process is
continuous
If water freezing in the installation is suspected, check whether safety
piping is not blocked The water added to the water charge in the
installation shall return through the overflow pipe from the pressure
vessel. If safety piping is blocked, the boiler must not be ignited, and
if it has been operating, proceed as in boiler emergency shutdown
procedure (see section 3.6).
It is forbidden to:
- spill water onto the grate
- ignite the boiler using flammable liquids
After the end of the heating season (April
÷
September), pay special
attention when using the boiler for heating the household hot water
only Boiler power will be too high relative to the absorption capacity
of the boiler, therefore it will be necessary to charge less fuel than
during normal burning in winter season and to monitor the
thermometer.
If the temperature raises above 80˚C, it will be necessary to open the shut-
off valve and let the hot water flow into the central heating installation, close the
chimney damper (shut off the blower). If possible, open hot water taps in the
home (e.g. in bathtub) and drain the hot water.
Each Moderator boiler is equipped with a stub pipe intended for safety
valve installation. It is absolutely necessary to install the valve, additionally the
manufacturer recommends installation of a thermal protection,which would
protect the boiler against excessive pressure rise. (Keep in mind that the thermal
protection will activate only if the installation pressure is not lower than 2.3 bar
and if the safety valve is installed).