background image

English

   18 

 

 

 

 

Regularly clean the filter scale, in order to avoid congestion. 

 

Do not clean the water heater cover with acidic or alkaline cleaning detergent; after cleaning 
the heater with neutral detergent, please cut off the power. 

 

 

 

 

Error Code

 

Malfunction phenomenon 

Causes

 

Handling method

 

E1

 

The buzzer ring 5 times, 
and the green light is on 

Power leakage 

Close the water tap, cut 
of the power, and 
contact with the 
maintenance department 

E2

 

The buzzer ring 5 times, 
and the green light is on 

Electric leakage coil 
malfunction 

Close the water tap, cut 
of the power, and 
contact with the 
maintenance department 

E3

 

The buzzer ring 2 times, 
and the green light is on 

Water outlet temperature 
sensor open circuit 

Contact with the 
maintenance department 

Outlet temperature sensor 
open circuit 

Contact with the 
maintenance department 

E4

 

The green light is on 

The water outlet 
temperature more than 
55

o

Adjusting water flow 

L2

 

The green light is on 

Not enough water flow 

Adjusting water flow 

 

 

 

 

Part 7: 

Electric Diagram

 

Part 5:

 Maintenance

 

Part 6:

 Trouble Causes & Handling Method

 

Содержание EI 3D Series

Страница 1: ...EI 3D BUKU PETUNJUK PENGGUNAAN PEMANAS AIR DAN KARTU GARANSI ELECTRIC INSTANT WATER HEATER MANUAL AND WARRANTY CARD 01 17 www modena co id ...

Страница 2: ......

Страница 3: ...Anda peroleh Simpanlah buku petunjuk pengoperasian ini dekat dengan Water Heater Anda agar sewaktu waktu jika diperlukan mudah untuk mendapatkannya Sertakan buku petunjuk pengoperasian ini jika Water Heater ini dialihkan kepada pihak lain dengan demikian pemakai yang baru dapat segera memahami cara penggunaan Water Heater ini Terima kasih atas kepercayaan Anda untuk memilih produk MODENA SELAMAT A...

Страница 4: ... 1 Nama nama bagian 3 Bagian 2 Penggunaan dan karakteristik 3 Bagian 3 Instalasi 4 Bagian 4 Cara penggunaan 6 Bagian 5 Perawatan 8 Bagian 6 Penelusuran masalah Cara mengatasinya 8 Bagian 7 Diagram elektrik 8 Bagian 8 Spesifikasi 9 NOMOR P 20 INDO3 00201 0212 ...

Страница 5: ...mbungan saluran air hal tersebut bisa merusak barang atau struktur penyangga di bawah pemanas air Bila terjadi masalah pada sistem arde segera hentikan penggunaan pemanas air Cabutlah steker pemanas air dari stopkontak atau putuskan semua sambungan dengan catu daya listrik dan hubungi Modena atau teknisi profesional Katup multi fungsi harus terpasang pada saluran air masuk Alat ini dapat digunakan...

Страница 6: ...t PEMAKAIAN FITUR Fungsi Air dari pemanas air ini dapat digunakan untuk mencuci piring menggosok gigi dan sebagainya Fitur Material baik Menggunakan badan plastik ABS buatan bebas korosi dan tahan lama elemen pemanas bertekanan dari baja tahan karat khusus berkualitas tinggi pencegahan kerak usia pakai panjang Pemutus arus termal termostat Komponen komponen lain didapatkan dari pabrik terkenal di ...

Страница 7: ...k yang dipasang di dinding Pemanas air harus dipasang di tempat yang a Tidak digenangi air dan tidak dapat mengalami pembekuan b Memiliki saluran air tersendiri c Memiliki ruang yang cukup untuk perawatan dan perbaikan d Memiliki pasokan air tidak kurang dari 4 kali kapasitas pemanas air e Tidak ada kebocoran gas yang dapat terbakar atau gas yang sangat korosif Tidak memiliki efek magnetik listrik...

Страница 8: ...lam ruangan lokasi pemasangan haruslah tidak terkena cahaya matahari dan hujan Untuk menghindari hilangnya panas pemanas air hendaknya dipasang dekat dengan lokasi pemakaian air panasnya Bila pemanas air tidak digunakan untuk waktu lama lepaskan selang air dan buang air dalam tangki pemanas Catatan Kecuali untuk katup multi fungsi yang disertakan dengan pemanas air komponen lain dapat diganti sesu...

Страница 9: ... air L menit d Petunjuk tampilan fungsi operasi Saat pemanas air mulai bekerja indikator kerja akan tampil dari kiri ke kanan dan sesuai laju aliran air terdapat tiga kecepatan bacaan Saat laju aliran besar indikator akan menyala dengan cepat dan sebaliknya e Tampilan kode masalah Bila terjadi masalah kode masalah error akan tampil dan lampu hijau di kanan layar juga akan menyala Untuk rincian men...

Страница 10: ... listrik dan hubungi bagian perawatan E2 Nada peringatan berbunyi 5 kali dan lampu hijau menyala Masalah kebocoran koil listrik Tutup keran air matikan aliran listrik dan hubungi bagian perawatan E3 Nada peringatan berbunyi 2 kali dan lampu hijau menyala Sirkuit terbuka pada sensor temperatur air keluar Hubungi bagian perawatan Sirkuit terbuka pada sensor temperatur air keluar Hubungi bagian peraw...

Страница 11: ...alitas produk desain dan spesifikasi diatas dapat berubah setiap saat tanpa pemberitahuan Gambar pada buku ini bersifat skematis dan bisa saja tidak tepat sama dengan produk aktual Nilai yang tercantum pada label atau dalam dokumentasi yang menyertainya diperoleh di laboratorium sesuai dengan standar yang relevan Nilai nilai dapat bervariasi tergantung pada kondisi operasional dan lingkungan dari ...

Страница 12: ...Bahasa Indonesia 10 ...

Страница 13: ......

Страница 14: ...hooting As a manufacturer of user friendly home appliances we thrive to simplify the description in this manual to facilitate the users In order for this Water Heater to perform normally for an extended period of time we highly recommend not only the buyer to hold onto this manual but also those who wish to operate the product optimally to maintain its service period and quality This manual is rec...

Страница 15: ...roduction 11 Part 1 Name of parts 13 Part 2 Usage and characteristics 13 Part 3 Installation 14 Part 4 How to use 16 Part 5 Maintenance 18 Part 6 Trouble causes handling method 18 Part 7 Electric diagram 18 Part 8 Specification 19 ...

Страница 16: ...er heater or the connector will damage the object or lower construction near the heater When the grounding system is in abnormal work you should stop using the heater at once Unplug the power plug or disconnect all connection with power supply circuit and contact the manufacturer of professional personnel The multi functional valve must be installed in the water inlet This appliance can be used by...

Страница 17: ...cale prevention long service life Thermal circuit breaker thermostat or other main parts are purchased from the famous manufacture from home and aboard Energy and electricity saving Heating quickly obvious energy saving Safe and reliable Strict enforcement of national standards sensitive leakage prevention over temperature prevention and over pressure prevention dry heating protection Get the secu...

Страница 18: ...ling hole picture in the accessory bag with the drill whose diameter is smaller than the plug bolt hook Then use a hammer to knock the plug bolt hooks into the holes and then fix the wall hang board with screw See the pic 4 Lift the water heater move slowly forward until the hook hand the product and lock the screw Pull down left right once to make sure the heaters is fixed Note The two plug bolt ...

Страница 19: ... with not to turn off the water tap in the outlet pipe function with no shower off the water function and the other is not to turn off the water function accessories Display pattern introduction Key instruction There are three touch keys on the water heater a ON OFF turn on or turn off the buzzer will ring once every operation b The up key When you operate this key once current gear will be displa...

Страница 20: ...s big the indicator will light quickly vice verse e The error code display When malfunction occurs error code will be displayed meanwhile the green light on the right of the digital tube will be on as well The detail error code explanation please check the Trouble Causes Handling Method Operation Method a Switch on the power Switch on the power the display and the indicator display 3s after that t...

Страница 21: ...ent E2 The buzzer ring 5 times and the green light is on Electric leakage coil malfunction Close the water tap cut of the power and contact with the maintenance department E3 The buzzer ring 2 times and the green light is on Water outlet temperature sensor open circuit Contact with the maintenance department Outlet temperature sensor open circuit Contact with the maintenance department E4 The gree...

Страница 22: ...cifications of this appliance may change without notice to improve the quality of the product Figures in this manual are schematic and may not match your product exactly Values stated on the machine labels or in the documentation accompanying it are obtained in laboratory in accordance with the relevant standards Depending on operational and environmental conditions of the appliance values may var...

Страница 23: ......

Отзывы: