(5)
LED Light Indicator (ES 10DR)
The Red “Heating” LED will remain ON during the heating process.
The Green “Ready” LED will turn on when the water temperature
reaches the user setting at the end of the heating phase; while the
Red LED will turns off.
Detailed Description of Functions
Heating/Heat Preservation Function
The system could identify the heating/heat preservation state and
will light up the corresponding indicator if there is a difference
between the actual temperature and the set temperature. When
the water heater is in the heating state, the “HEATING” indicator
will lights up (bright green), while the “READY” indicator lights up
(bright red) when in the heat preservation state.
The water heater could be directly heated to the set temperature
after it is just started or re-adjust the temperature. When the set
temperature is reached, the water heater will stop heating and
enter into the heat preservation state. If the difference between
the actual temperature and the set temperature is greater than the
previous temperature difference, the water will be heated again.
Booking Bath Function
When the appliance is in the power-on state, press the “BOOK”
button (
). Then, the booking indicator will light up. The system
will enter into booked time adjustment state and the digital display
on the tank(tube) will flickers. At this moment, the user could adjust
the booked time for the heating process through pressing “+”or “-
”button
Delay Booking Function
This appliance adopts the delay booking function. By this function,
the hot water is available after “XX” hours (user’s set time). When in
the booking (heating time programming) state, the user cannot only
adjust the booked time circularly in the range of “01-02…-24-01” by