CONT. 5. REPEATER FUNCTION
2. On the remote control, press the button sequence:
UP, STOP, DOWN, UP, STOP, DOWN
. Activation of
the repeater function will cause three sequences of
DOWN-UP
micro-movements by the actuator.
3. Repeat step 1 to deactivate the repeater function. Then press the button sequence:
UP, STOP,
DOWN, UP, STOP, DOWN
- confirmation of deactivation is the execution of two sequences of
micro-
DOWN-UP
movements by connected tubular motor.
WARNING!
Turn on the repeater function only on devices that are within range of the signal
range. Because of the efficient work, we recommend that you enable the signal repeater
function on up to three devices in the facility. Unreasonable inclusion of signal repeater on
many devices may cause interference in all radio equipment.
Fig. 5
b
MASTER
a
2X
6. BIDIRECTIONALITY
MOBILUS C-MRBT
with two-way communication with the remote control allows control of the
state of shutter position ( eg. open, closed, intermediate level, overload detection ).
Proper operation of bidirectional communication requires the use of pilots with bidirectional
communication.
Remote controls supporting two-way communication:
MOBILUS COSMO | HCT, COSMO | G3+,
COSMO | HM, COSMO | HB, COSMO | WT9, COSMO | WT.
13