![MOBILTEX CorTalk SPI1 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/mobiltex/cortalk-spi1/cortalk-spi1_installation-and-operating-instructions-manual_1815789033.webp)
MOBILTEX® DATA LTD.
TITLE:
Installation and Operating Instructions
Calgary, Alberta
DOCUMENT NO.:
SPI1-MAN-001
SHEET:
33 of 57
REV:
1.14
Figure 30 corTalk® Portable Interrupter Scheduler Menu Page 4
SCHEDULER MENU
[1]S1 [4]S4 [7]S7
[2]S2 [5]S5 [0]MAN
[3]S3 [6]S6
SCH1 PG4
[0]MORE
[1]NOTES
[2]DL EN
[3]FILTER
*Schedule page 4 options only available on SDL1
equipped devices.
NOTES
Data entry area (60
characters maximum).
Free form notes entry parameter. Parameter does not
affect operation, but is stored in the resultant data file.
Alphabet characters are entered using the numeric
keypad in a manner similar to the text messaging entry
commonly available on many cell phones.
DATALOGGER ENABLE
YES
1=YES,0=NO
Enable/disable datalogger operation on current schedule.
DIG. FILTER ENABLED
YES
1=YES,0=NO
Enable/disable a 60Hz digital filter on the current
schedule. The digital filter in the datalogger will
suppress 60Hz noise by an additional 27dB over the
hardware filtering (54dB).