Zeus200 

                                     

      Installation manual 

V 1.0.7 - 12/10/2020 

          Page 24 of 28 

 

3

 

Installer Menu 

 

3.1

 

Menu activation 

 

To access the Generator Installer menu, activate the Maintenance menu, click the central icon of the 
Zeus200 generator and enter the password 3105, confirming with OK. 
In this menu it is possible to display the operating parameters of the heating and cooling system, 
activate the water pump to verify the cooling system during the first start-up and to activate the fuel 
pump to purge the supply circuit. The procedure for the water and fuel pump activation are specified 
in the "First start-up" chapter. 
 

 
 
 
 
 
 
 

 

 
 
 
 
 

 

The first line of the menu also shows the data (HS) of the heat sink temperature. With the Zeus 150 
generator running at full speed, an HS temperature above the outlet temperature (OUT) is an 
indication of the presence of air bubbles in the cooling liquid system, for which it needs further 
verification. The lower the HS temperature the better the system works.

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

From  the  Maintenance  menu  it  is  possible  to  activate  the  Control  Unit  Installer  screen,  typing  and 
confirming the password 3105. From this screen it is possible to check the data related to the voltage 
of the sources and the temperature of the control unit. There is a button for the forced activation of 
the generator, useful in case you want to turn on the generator, by-passing the detection of battery 
charge/discharge, or the not-completed cooling phase. 

 

 

 

Содержание ZEUS200

Страница 1: ...S200 BD Power Supply Diesel IMPORTANT As reported in the warranty conditions available on our website the warranty becomes void if the instructions in the installation manual are disregarded More info...

Страница 2: ...Components list 10 2 2 2 Mounting instruction 10 2 3 Exhaust gas line 12 2 3 1 Components list 12 2 3 2 Mounting instruction 12 2 4 Fuel supply line 13 2 4 1 Components list 13 2 4 2 Mounting instruc...

Страница 3: ...e of use causes the immediate loss of legal and or commercial warranty The following situations entail the loss of warranty and liability claims by the manufacturer Inappropriate assembly Use of faste...

Страница 4: ...When using a separate fuel tank separate the filler neck must not be placed in the passenger compartment and must be fitted with a perfect closing cap to prevent leakage The filler neck must be clearl...

Страница 5: ...comply with the law and safety regulations as well as repairs carried out by unauthorized personnel even if with original spare parts relieves Mobil Tech Srl of any responsibility The law is binding a...

Страница 6: ...lar must not be occupied by other objects and must be absolutely clear Above or near the generator it is forbidden to store or transport flammable objects fuel cans oil cans sprays gas cartridges fire...

Страница 7: ...erator Discharge Power Electricity 10 1 trough hull 11 1 drain pipe 24 28 12 1 600mm dip tube 13 1 fuel Rilsan pipe 2x4mm 14 1 user manual 15 1 installer manual 16 1 fuel pump generator cable 17 1 ext...

Страница 8: ...2 1 Generator 2 1 1 Components list Code Description N 1 Z200BD12 Zeus200 generator 1 pc Envelope 1 Code Description N 2 Z200 10 001 Inox generator bracket 50x150mm thickness 4mm 4 pcs 3 Z 01 011 Scr...

Страница 9: ...are no objects inside the installation compartment that can move and hit the Zeus200 generator 6 To install the Zeus200 generator use the 4 brackets 2 fixing them with screws 3 and washers 4 or create...

Страница 10: ...rline fit the supplied water filter 1 The filter must be positioned so that it can be checked and if necessary cleaned or replaced 2 Immediately after the filter place the supplied external water pump...

Страница 11: ...oise Installation notes _______________________________________________________________________ _______________________________________________________________________ ________________________________...

Страница 12: ...6x18x2mm A4 1 pc 8 Z 01 034 Nut M6 A4 1 pz 2 3 2 Mounting instruction 1 The drain line must be directed towards the stern or the side of the boat The exhaust line must not pass under the generator as...

Страница 13: ...drain hose reaches temperatures above 200 C so make sure that it cannot come into contact with anything The thermal bandage must be handled with gloves and must be immersed in water before use in orde...

Страница 14: ...of the circuit Use the 6 clamps 7 9 for the intermediate connections between the fuel rubber hose and the rilsan hose 7 Mount the fuel pump near the tank in longitudinal position compared to the hull...

Страница 15: ...le 2x6mm l 1 5mt 1 pc 6 Z1 2 11 017 Cable for generator and fuel pump wiring L 6 mt 1 pc Envelope 5 Code Description N 7 Z 02 009 Nylon cable tie 130x2 5mm 1 pc 8 Z 02 010 Nylon cable tie 200x4 8mm 10...

Страница 16: ...ired for installation The following picture shows the cable entries on the front side of the control unit the table shows the types of cables to be passed through each cable entry In case of unused en...

Страница 17: ...re 6mm 1 2 Generator Red wire 6mm 1 3 Generator Brown wire 4mm 1 4 Generator Green wire 4mm 1 5 Sola panel opt Negative 2 6 Solar panel opt Positive 3 7 Engine battery opt Negative 5 8 Engine battery...

Страница 18: ...n the clamp spring insert a slotted screwdriver in the rectangular seat as shown and remove the screwdriver after the cable has been positioned Then check the perfect seal by pulling the cable outward...

Страница 19: ...sor connections Using the appropriate cable 1 pag 15 perform the following operations 1 Place the sensor in the battery compartment but not on the battery securing it using the special adhesive 2 Pass...

Страница 20: ...gine battery Note For battery selection follow carefully the instruction given in chapter First start up 2 5 10 Primary battery connections 12V model Z200BD12 24V model Z200BD24 Using the appropriate...

Страница 21: ...ator itself Check that inlet and outlet pipes are correctly connected and blocked and that the seacock safety valve is open The pump works strictly in the presence of water and not dry In the event of...

Страница 22: ...Battery EE_VEoCBatt1 1 14 2V 25 C 28 4V 25 C EE_VLB 7 12 2V 23 8V EE_VELB 6 13 5V 13 5V EE_Tabs 0 1h 1h EE_VExitFloat 19 12 5V 25V ON OFF Lead Acid Free FLOOD Primary battery EE_VEoCBatt1 0 14 8V 25 C...

Страница 23: ...y Now the generator is ready to be used Activate the automatic or manual mode as described in the user manual Installation notes _______________________________________________________________________...

Страница 24: ...rst line of the menu also shows the data HS of the heat sink temperature With the Zeus 150 generator running at full speed an HS temperature above the outlet temperature OUT is an indication of the pr...

Страница 25: ...e update and the checks performed by the system It is also possible to reset the error by pressing the reset button at the bottom left ATTENTION pressing the reset button will also reset timers mode a...

Страница 26: ...ntilated place Display shows Engine batt low Low voltage of engine battery Turn on the generator and force the charge on the engine battery Switch on vehicle s engine if possible Display shows Too low...

Страница 27: ...erature too high Wait for the coolant temperature to drop Display shows Water outlet probe error Fault or lack of connection with outlet water probe Check sensor connection and operation Display shows...

Страница 28: ...thermal delta energy production varies according to the sea temperature Furthermore the system can be conditioned by other factors that modify combustion and efficiency such as humidity and air rarefa...