6.3.4 Alarms
Tab
The alarms displayed in the Alarms tab corresponds to the system element selected in the
topology tree and vary depending on whether a VCU or VAP is selected.
6.3.4.1
VCU Alarms Tab
When a VCU element is selected in the topology tree, the Alarm tab displays the main alarms in
the unit.
To access Alarms Tab of VCU
In the Topology Tree, click the Control Unit (VCU), click the Config(uration) tab in the menu
bar located at the top of the window and click the VCU Alarms sub tab.
If one or more alarms occur, the corresponding Status indicator is illuminated in RED. If the VCU
is OK and no fault occurs, the Overall Status indicator will show GREEN.
Alarm
Description
Service 1/2 DL RF Pwr Low
Input power of specific service lower than 5dBm
Service 1/2 DL RF Pwr High
Input power of specific service is higher than maximum expected
power defined in the RF tab
Service 1/2
User has disabled service
Overall temperature
Temperature of unit exceeds normal range
CU faulty
Hardware fault detected in VCU
Overall status