MobileAccess™ 1000/1200
Introduction
UM-1000, Revision 2.2
V
WARNING:
The MobileAccess
TM
system uses an optical laser for transmitting voice and
data. The laser unit has the following output characteristics:
- Optical output power (mW):
≤
3.0
- Wavelength (nM): 1310 ± 10
WARNING:
Applying power to the MobileAccess™ creates a laser energy source operating
in class
I
as defined by IEC 60825-1, 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice no. 50 (July 26, 2001). Use either an infrared viewer, optical power
meter or fluorescent screen for optical output verification.
WARNING:
The use of controls or adjustments or performance procedures other than those
specified herein may result in hazardous radiation exposure.
WARNING:
Compliance with RF safety requirements:
MobileAccess™ products have no inherent significant RF radiation.
The RF level on the down link is very low at the remote hub unit downlink ports. Therefore,
there is no dangerous RF radiation when the antenna is not connected.
The design of the antenna installation needs to be implemented in such a way so as to
ensure RF radiation safety levels and non- environmental pollution during operation.
ATTENTION:
To avoid damaging your product, please observe the following:
•
Always keep the optical connector covered. Use the fiber optic cable or a protective
cover. Do not allow any dirt and/or foreign material to get on the optical connector
bulkheads.
•
The optical fiber jumper cable bend radius is 3 cm. Smaller radii can cause excessive
optical loss and/or fiber breakage.
•
For proper system performance only use cables equipped with
SC/APC connectors to connect to the MobileAccess system.
Содержание 1000 System
Страница 10: ......