MobileAccess™ 1000/1200
Connections
UM-1000, Revision 2.2
21
3.2.3.1 Wall Mount
RHU 1000 is usually mounted on a wall in a clean indoor environment –
RF ports
facing down
.
Assembly instructions
1. Place the unit against the wall and mark the four holes to be drilled in the wall.
2. Drill four holes 8mm in diameter and insert the appropriate sized plastic plugs in
each hole.
3. Secure the RHU 1000 to the wall using four screws, 4.5mm diameter, 40mm
long.
Figure
3-10. RHU 1000 Wall Mount
3.2.3.2 Connections
1. Install splice box near RHU (refer to Figure
2-1).
2. Connect fiber optic cable to splice box and to SC/APC pigtails to RHU
3. For the downlink, connect the fiber optic cable pigtails from splice box
coming from the Base Unit port to the corresponding Remote Hub
Unit port.
4. Connect the Remote Hub Unit to antennas according to the RF
engineers design. (up to 4 antennas per RHU).
5. For the uplink, connect the fiber optic cable pigtails from splice box
from the Remote Hub Unit to the uplink port that connects to the Base
Unit.