MobileAccess™ 1000/1200
Connections
UM-1000, Revision 2.2
19
3.2.2.2 BU Rear Panel
The BU rear panel contains all the RF connections.
Figure
3-6. Base Hub Unit Rear Panel (RF Connections)
Table
3-3. MobileAccess 1000 Front Panel Indicators
Connector
Description
Uplink output
Uplink connectors to be connected on BTS side.
Downlink input
Downlink connectors to be connected on the BTS side.
Com Port RS485
Connection to MobileAccess 410/430 controller.
PWR
Power connection
3.2.2.3 Base Unit to RHU connections
1. It is assumed that the patch panel cabinet (SC/APC adaptors) for fiber optic
cable connections is installed in the rack near the Base Units.
2. Connect (3/125/900) pigtail with SC/APC connectors between splice
tray and patch panel cabinet.
3. Connect (3/125/3000) SC/APC jumpers between the corresponding
Base Unit and patch panel.
4. Connect the fiber optic cables from the Base Unit to the RHU’s
through the patch panel cabinet.
Figure
3-7. Base Hub Unit Rear Panel (RF Connections)
Laser output connection
to RHU
Optical diode input
from RHU
Base Unit Laser
operational LED indicator
RHU LED indicators
(Link 1 to 8)
RS232 connection for
monitoring
Power indicator
Pair of uplink and downlink connections
for interface to BTS side (all four
connectors must be connected)
Alarms connector