MobileAccess™ 1000/1200
Connections
UM-1000, Revision 2.2
23
Figure
3-13. RHU 1200 Front Panels
Table
3-5. MobileAccess 1000 Front Panel Indicators
LED
Description
RUN
When blinking, indicates that the CPU in the RHU is in normal
operating mode.
DC Power
ON
3.2.4.1 Assembly and Connections
Refer to Figure
3-14.
ATTENTION
To prevent damaging the SMA connectors,
be sure to tighten using a torque of 8lb.
1. On the RHU 1200 front panel,
short (interconnect)
the pair of
SMA Downlink
connectors to each other using the ‘
U-shaped’
jumpers, and the pair of
SMA
Uplink
connectors to each other. Using the second
U-shaped
jumper.
2. Position the supplied bracket on the RHU 1000 and secure the
bracket
to the
RHU 1000
using the four supplied
6-32 NC
screws.
3. Position the RHU 1200 unit on the bracket and secure the
RHU 1200
to the
bracket
using the four supplied
8-32
screws.
4.
Interconnect
the RHU 1000 and RHU 1200 SMA
Uplink
,
Downlink
and
High
connectors on the rear panels of both units using the
three
straight
jumpers.
5.
Interconnect
the RHU 1000 and RHU 1200
D-type 9-pin
connectors on the rear
panels of both units using the supplied flat-cable.
6. Connect the power to the RHU 1200 front-panel
DC
connector.