Environmental Protection 
 

If your device needs replacement, or 

don’t use it, consider the environment: 

 
1) Do not dispose of your device along with the municipal waste (this is also 
the importance of the stated recycling symbol). 
2) Contact your municipal authority to indicate the point of disposal of your 
device for recycling. 
3) With the most useless your device in the right place 
Recycling helps to protect the environment and the operation again your 
device materials. 

16 

EC Declaration of Conformity 

We declare the conformity of the above product to the provisions of the Medical Equipment 
Directive 93/42/EEC and the Greek National Legislation ΔΥ8δ/Γ.Π.οικ.130648. ΦΕΚ 
2198Β/02-10-2009 

Each product in this statement meets the technical specifications contained in its technical 
documentation 

If the appropriate maintenance will be provided and the product will be used according the 
“instruction of use”  then the product is safe and effective and does not endanger the health 
safety of patient’s, user and or third parties,  

This statement is issued  based on the certificate of registration in the Register of 
Manufacturers of Medical Devices in National Organization for Medicine 

The product belongs in Class I,  Classification rule 1 & Corresponds to the Medical Device 
Directive: 93/42/EEC 

Содержание 0806288

Страница 1: ...ANUAL ANTI DECUBITUS HOSPITAL STRIPED MATTRESS 5 3 FOAM MATTRESS AIR PUMP EL EN REF 0806288 Read the instruction manual before use and keep it for future reference Important safety instructions Versio...

Страница 2: ...15 Stage to II EL 12 2 ON OFF...

Страница 3: ...3 30 180 kg 10kg 4 L 5 LED 30 2 1 OFF 4 ALARM 5 5 3 0806289 5 3 0806290 DIGITAL 3...

Страница 4: ...1 2 3 4 5 6 CPR 3 4 5 6 7 1 2 4 1 2 5 3 4 6...

Страница 5: ...Pressure CPR CPR CPR 5 V Hz 220 VAC 50HZ 7 30mmHg 60mmHg 12 min 7 W 10 30 dB 10 x x 27 5 x 13 5 x 9 cm 2 Kg 12 Touch On Off soft button 155 Kg Nylon TPU Stretch PU 20 cm 0 22 mm 200 x 90 cm 18 cells 1...

Страница 6: ...6...

Страница 7: ...7...

Страница 8: ...1 2 3 8 93 42 8 130648 2198 02 10 2009 T 1 1 93 42...

Страница 9: ...To 2 6 S N LOT 96 98 30 28210 63222 www mobiakcare gr 9...

Страница 10: ...r the stripped mattress Place the air mattress over the bed mattress having first stretch the bottom sheet making sure the air inlet is at the side of the legs Secure it with fixing straps below the m...

Страница 11: ...Use only for nursing treatment 2 LOW PRESSURE If the air pressure is lower than the specified level an alarm can be triggered where it can be recalled 1 OFF Soft button 4 In the event of a power failu...

Страница 12: ...nd up or place it on a firm flat surface Connect the quick links as shown in the pictures left Front Back 3 Quick connection male 4 Fuse 5 Filter 6 Filter cover 7 Bed hooks 1 Control Panel 2 Quick Con...

Страница 13: ...ly pull the valve CPR to release air directly from the mattress The valve CPR is located on the right side at the top of the mattress Also remove the connection from the pump for an even faster deflat...

Страница 14: ...d If you need to save the mattress empty of air by folding it Keep or store the pump in a clean dry well ventilated environment Before cleaning the pump disconnect from the electrical supply Clean the...

Страница 15: ...e the pump is running Do not use sharp objects near the mattress Do not exceed the maximum load kg recommended by the manufacturer CAUTIONS IMPORTANT 15 CAUTION Do not use the product for a purpose no...

Страница 16: ...ve product to the provisions of the Medical Equipment Directive 93 42 EEC and the Greek National Legislation 8 130648 2198 02 10 2009 Each product in this statement meets the technical specifications...

Страница 17: ...from improper use poor maintenance modification abuse or non compliance with the product s operating instructions Damage or defects caused by natural disasters unauthorized maintenance or repair powe...