5.23 SYSTEM RESET
To reset a Mobeye CML2255 two steps are necessary:
1. Reset the Mobeye CML2255
2. Delete the Mobeye CML2255from the Mobeye Internet Portal
1. To reset the Mobeye CML2255 to its factory settings
1. Remove the batteries (and external power supply).
2. Press the outside button while reinserting the batteries. Keep it pressed for (about)
another 5 seconds.
3. Release the button immediately after the LED starts to flash.
4. If relevant, connect the external power supply.
After a successful reset, the status LED will blink green to indicate that the module is
not configured. The security code is back to factory settings as well.
2. To delete the Mobeye CML2255 from the Mobeye Internet Portal
Delete the device from the Mobeye Internet Portal. The SIM card could be then reused
for another Mobeye device, or the same device can be connected again.
In the device list, click the name of the device to go to the details screen. Next choose ‘
Device’. Click ‘delete’ to delete the device and confirm the option.
The SIM card will be disconnected from the device and visible on the first screen.