![background image](http://html.mh-extra.com/html/mobeye/thermoguard-cm2200/thermoguard-cm2200_user-manual_1814832008.webp)
7
2.2 CONNECT THE TEMPERATURE SENSOR(S)
Plug the external temperature sensor into the socket and
press it firmly.
2.3 INSERT THE BATTERIES
Insert the two batteries (CR123) in the module. Use the +/- indication for the correct
placement.
2.4 ENTER THE PROGRAM MODE
In order to program the unit, the GSM module needs to be open and connected to the
network. Using external power, the unit is always in program mode.
A battery-operated unit switches to the program mode after inserting the batteries. First
the GSM module establishes network connection. During this time the LED flashes
green and red. Within 10-30 seconds the connection is established and the status LED
starts flashing 1 sec. on/1 sec. off (or stays on continuously in case the first telephone
number has been configured).
The Mobeye ThermoGuard returns to the program mode by pressing the on/off button
for 5 seconds, until the LED starts flashing red/green. Once it has GSM connection it will
be flashing again (or stays on continuously).
As long as the unit is in program mode, the status green LED is on (or flashing 1 sec.
on/1 sec. off if the module has no configuration). During the first 3 minutes, the GSM
module remains active, ready to receive SMS commands. After 3 minutes a time-out
occurs and the GSM module switches off in order to save the batteries. The unit returns
to the low power operational mode.