Mobeye MS100BK Скачать руководство пользователя страница 7

2.4 CONNECT THE POWER SUPPLY 

The Mobeye  MS100BK is designed to run on batteries, or to use an external power supply 
(9-32VDC).  Using  external  power,  the  module  is  always  in  connection  with  the  GSM 
network.  This  gives  following  advantages:  a  longer  battery  lifetime,  possibility  to  receive 
power  failure  messages  (using the  batteries)  and  the  possibility  to  perform  remote  actions, 
such  as  arm/disarm,  switch  the  outputs,  ask  status  reports  and  to  program  it  via  SMS-
commands.  
 
Connect  the  external  power  adapter  (or  any  other  regulated  9-32VDC 
power supply) to the power input of the connector (press on the  orange 
pins for connecting the wires): 
 

 

V+ (black lead with white stripe) to “+” 

 

Ground (black lead) to “-“ 

 
If using the Mobeye mains adapter (Mobeye article 10027):  
The black wire with the white line 

is “+”, the other black wire is “-“. 

 
Close the Mobeye MS100BK using the 4 screws. 

2.5 PROGRAM THE PHONE NUMBERS 

You need to program at least one phone number in the unit as alarm number. 

 

  Enter your 4 dig

it code (factory setting: “1111”) 

 

Press “menu” 

 

Enter “101”  

 

Press “OK” 

  Enter the phone number (e.g. 0712345678 or 0044712345678) 

 

Press “OK” 

 

The light turns green and a confirmation melody is played. The Mobeye MS100BK is ready 
to use. 

2.6 CHECK THE SETTINGS 

The  settings  can  be  sent  to  the  programmed  telephone  number  as  SMS  text  message.  In 
this way you also check the correct working of the SIM card. 

 

Enter your 4 digit code (factory setting: “1111”) 

 

Press “menu” 

 

Enter “10”  

 

Press “OK” 

 
Within  ca.  30  seconds  the  programmed  phone  number  (TEL1)  will  receive  the  list  with 
settings. 

2.7 SWITCHING ON 

The  Mobeye  MS100BK  is  switched  on  automatically  after  programming  the  first  telephone 
number. To switch on/off manually, please refer to 3.1. 

 

 

+ -

 

Содержание MS100BK

Страница 1: ...Installation manual Mobeye MS100BK GSM Measure Control and Alarm module SW version 7 n...

Страница 2: ......

Страница 3: ...F 10 6 6 Interval test message 10 6 7 Set actual time and date 10 6 8 Automatic time based arm disarm 11 6 9 identification text 11 6 10 Alarm text 11 6 11 Input type 11 6 12 Input delay time 11 6 13...

Страница 4: ...nded for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflamma...

Страница 5: ...ing the text such as Mobeye Input 1 OK or Mobeye Input 2 OK If the sensor and or the input remain in the alarm status the Mobeye MS100BK repeats sending the SMS alarm message every four hours With jus...

Страница 6: ...he back cover Insert the SIM card in the holder For opening closing move the cover slightly 2 2 CONNECT A SENSOR Open the hole in the enclosure and insert the 2 wires of an external sensor through the...

Страница 7: ...10027 The black wire with the white line is the other black wire is Close the Mobeye MS100BK using the 4 screws 2 5 PROGRAM THE PHONE NUMBERS You need to program at least one phone number in the unit...

Страница 8: ...ablish a connection to the network First an SMS text message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm usi...

Страница 9: ...o remotely control the system Please find below the architecture of the main unit Inputs External sensors can be connected to the inputs Upon closing or opening an input the Mobeye MS100BK will send a...

Страница 10: ...To program a telephone number at memory position 2 1111 MENU 102 OK 004934578692 OK To set the SMS to OFF just call 1111 MENU 12 OK 0 OK 5 2 CONFIGURATION VIA SMS TEXT MESSAGES Almost all options can...

Страница 11: ...th SMS commands is listed chapter 8 The commands are case sensitive Several commands may be combined in one SMS message with a maximum of 160 characters by placing a between the commands A confirmatio...

Страница 12: ...OFF By default the Mobeye MS100BK sends alarm notifications via text message and calls to the preset contact persons By turning off the SMS the unit will only call after the sensors send an alarm 6 5...

Страница 13: ...an input is set to NO the alarm will be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered if the connection between the input terminals is bro...

Страница 14: ...them be switched by any incoming call SMS without being authorised To disable the need for authorised numbers the authorization option can be set to OFF Default is ON 6 17 DURATION OF OUTPUTS SWITCH...

Страница 15: ...puts 2 Power failure Send SMS call 3 Power restored Send SMS 4 Input 1 triggered Send SMS call 5 Input 2 triggered Send SMS call 6 Input 1 restored Send SMS 7 Input 2 restored Send SMS The SMS texts a...

Страница 16: ...ION1 REACTION2 REACTION3 Do not forget the space between CODE and the TRIGGER The Mobeye MS100BK will play a short melody to indicate a successful configuration In case of a wrong command a long beep...

Страница 17: ...uence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its index number even if a rule with a previous number is deleted This will result in gap...

Страница 18: ...pad 71 0 off 1 NO 2 NC 1 NO SMS TYPEIN1 OFF NO NC Input type input 2 Keypad 72 0 off 1 NO 2 NC 1 NO SMS TYPEIN2 OFF NO NC Inactive time Input 1 Keypad 73 0 999 min 5 SMS INACTIVEINP1 Inactive time inp...

Страница 19: ...tification text Keypad SMS NAME 20 characters Mobeye Alarm text power failure Keypad SMS TEXT2 20 characters Power failure Alarm text power restored Keypad SMS TEXT3 20 characters Power restored Alarm...

Страница 20: ...EST GSM NETWORK STRENGTH Before using the Mobeye MS100BK is it advised to test the GSM signal strength at the location Enter the installation code Press menu Press 512 Press OK The Mobeye MS100BK will...

Страница 21: ...available belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes and then re enter th...

Страница 22: ...2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low volta...

Страница 23: ......

Отзывы: