Attention! Very important 
 

This user manual contains important guidelines for the installation and usage of the Mobeye

 

MS100BK. Please read these thoroughly before you start using the Mobeye

 

MS100BK! 

In case of damage caused by disregarding the guidelines, the warranty becomes void.  
The  user  must  regularly  check  the  proper  functioning  of  the  Mobeye  MS100BK.  The 
manufacturer cannot be held liable for any  damage  or loss caused by any incorrect use or 
incorrect functioning of the Mobeye

 

MS100BK. 

 

Safety guidelines 

•  The  permitted  ambient  temperature  during  operation  may  not  be  exceeded  (not  lower 

than -10°C and not higher than 55°C). 

•  The device is intended for use in dry and clean places. 
•  Protect the device from moisture, heat and water splashing. Not intended for external use. 
•  The guidelines for the battery usage must be regarded.  
•  Do not expose the device to strong vibrations. 
•  Do not let it fall from height. 
•  Do not use in an environment where any inflammable gases, vapours or dust are present 

or could be present.  

•  Repair of the device may only be carried out by people, trained for Mobeye

®

 repair. 

•  If the device must be repaired, only original replacement components may be used. The 

use of different parts may lead to damage of the Mobeye MS100BK. 

 
Use in accordance with the regulations 

The purpose of this device in accordance with the regulations is the generation of SMS text 
messages  and  telephone  calls  after  the  activation  of  one  of  the  inputs,  or  after  an  internal 
trigger;  switching  the  outputs  after  an  alarm  or  via  incoming  call/SMS.  Other  uses  are  not 
permitted. 
 

Battery recycling 

CR123  batteries,  as  used  in  the  Mobeye  MS100BK  can  be  recycled.  Please  take  empty 
batteries to a nearest collection point. 

Содержание MS100BK

Страница 1: ...Installation manual Mobeye MS100BK GSM Measure Control and Alarm module SW version 7 n...

Страница 2: ......

Страница 3: ...F 10 6 6 Interval test message 10 6 7 Set actual time and date 10 6 8 Automatic time based arm disarm 11 6 9 identification text 11 6 10 Alarm text 11 6 11 Input type 11 6 12 Input delay time 11 6 13...

Страница 4: ...nded for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflamma...

Страница 5: ...ing the text such as Mobeye Input 1 OK or Mobeye Input 2 OK If the sensor and or the input remain in the alarm status the Mobeye MS100BK repeats sending the SMS alarm message every four hours With jus...

Страница 6: ...he back cover Insert the SIM card in the holder For opening closing move the cover slightly 2 2 CONNECT A SENSOR Open the hole in the enclosure and insert the 2 wires of an external sensor through the...

Страница 7: ...10027 The black wire with the white line is the other black wire is Close the Mobeye MS100BK using the 4 screws 2 5 PROGRAM THE PHONE NUMBERS You need to program at least one phone number in the unit...

Страница 8: ...ablish a connection to the network First an SMS text message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm usi...

Страница 9: ...o remotely control the system Please find below the architecture of the main unit Inputs External sensors can be connected to the inputs Upon closing or opening an input the Mobeye MS100BK will send a...

Страница 10: ...To program a telephone number at memory position 2 1111 MENU 102 OK 004934578692 OK To set the SMS to OFF just call 1111 MENU 12 OK 0 OK 5 2 CONFIGURATION VIA SMS TEXT MESSAGES Almost all options can...

Страница 11: ...th SMS commands is listed chapter 8 The commands are case sensitive Several commands may be combined in one SMS message with a maximum of 160 characters by placing a between the commands A confirmatio...

Страница 12: ...OFF By default the Mobeye MS100BK sends alarm notifications via text message and calls to the preset contact persons By turning off the SMS the unit will only call after the sensors send an alarm 6 5...

Страница 13: ...an input is set to NO the alarm will be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered if the connection between the input terminals is bro...

Страница 14: ...them be switched by any incoming call SMS without being authorised To disable the need for authorised numbers the authorization option can be set to OFF Default is ON 6 17 DURATION OF OUTPUTS SWITCH...

Страница 15: ...puts 2 Power failure Send SMS call 3 Power restored Send SMS 4 Input 1 triggered Send SMS call 5 Input 2 triggered Send SMS call 6 Input 1 restored Send SMS 7 Input 2 restored Send SMS The SMS texts a...

Страница 16: ...ION1 REACTION2 REACTION3 Do not forget the space between CODE and the TRIGGER The Mobeye MS100BK will play a short melody to indicate a successful configuration In case of a wrong command a long beep...

Страница 17: ...uence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its index number even if a rule with a previous number is deleted This will result in gap...

Страница 18: ...pad 71 0 off 1 NO 2 NC 1 NO SMS TYPEIN1 OFF NO NC Input type input 2 Keypad 72 0 off 1 NO 2 NC 1 NO SMS TYPEIN2 OFF NO NC Inactive time Input 1 Keypad 73 0 999 min 5 SMS INACTIVEINP1 Inactive time inp...

Страница 19: ...tification text Keypad SMS NAME 20 characters Mobeye Alarm text power failure Keypad SMS TEXT2 20 characters Power failure Alarm text power restored Keypad SMS TEXT3 20 characters Power restored Alarm...

Страница 20: ...EST GSM NETWORK STRENGTH Before using the Mobeye MS100BK is it advised to test the GSM signal strength at the location Enter the installation code Press menu Press 512 Press OK The Mobeye MS100BK will...

Страница 21: ...available belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes and then re enter th...

Страница 22: ...2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low volta...

Страница 23: ......

Отзывы: