26
7.5
TECHNICAL MESSAGES
In the event of technical issues the telephone number programmed in at
position 1 (TEL1) receives an SMS message. Possible technical messages are:
Message
Reason
Low batteries, external power
supply OK
Power is available, batteries need to be replaced.
No external power supply,
batteries OK
No external power supply, batteries are able to take
over operation in low power mode.
Low batteries, no external power
supply
No external power supply, batteries need to be
replaced.
External power supply OK,
batteries OK
The external power is restored (or the adapter is
plugged in a socket), batteries do not need to be
replaced.
(delayed message)
If (delayed message) is added to the SMS text
messages, the message
couldn’t be sent
earlier, due
to a SIM card failure or GSM network failure.
Batteries too low. Module
shutting down.
The module has shut down due to low voltage.
Replace the batteries or connect the power supply to
restart the unit.
Module restarted. Power supply
[status]. Batteries [status].
The module has been able to restart after a
shutdown.
When receiving one of the above mentioned technical messages, please take
appropriate action as soon as possible.