![Mobatime DTS 4020.timebridge Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/mobatime/dts-4020-timebridge/dts-4020-timebridge_mounting-and-instruction-manual_1814702056.webp)
© MOBATIME
56 / 94
801299.00
6.6
Maintenance menu
DTS 4020.timebridge Moser-Baer AG
====================================
MAINTENANCE
1 Update software (FTP)
2 Update software (USB)
3 Backup configuration and log to USB
4 Backup configuration (local backup)
5 Restore configuration (local backup)
6 Restore configuration (default MOBA)
7 Restart device
99 Return
Enter desired menu number>
Path: 3 Maintenance
1. Initiating a software update (files must have been copied by FTP into the directory
/ram
of the DTS 4020 before).
See chapter "7 Updates".
The command always leads to a restart of the DTS 4020 (even if no files were
copied for update).
Notice:
Possibly save configuration first.
2. Initiate a software update (files must first be put onto a USB stick and this stick
must be connected to the DTS 4020).
See chapter "7 Updates". The command
always leads to a restart of the DTS 4020 (even if no files were copied for update)
Notice:
Possibly save configuration first.
3. Save the entire configuration and the log files on a USB stick . Also generates a
diagnosis file (dts4020system_xxxxxxxxxxxx.log) in the directory /ram which is also
copied on to the USB stick or which can be downloaded per FTP (only for support).
4. Backup the entire configuration locally (
file dts4020.conf.bkp is created).
5. Restore the entire configuration from a backup stored locally.
6. Restore the entire configuration to factory settings.
7. Restart DTS 4020.
See also chapter "7 Updates".