Time adjustment / Time-keeping
DTS 4020.timebridge Moser-Baer AG
====================================
TIME ADJUSTMENT CONFIGURATION
Adjust mode (0=follow, 1=set) 0
Max. catch up speed 50ns/s
Time core type (0-255, default 0) 0
4 Synch. only offset 0ms
5 RTC mode 0
98 Return and save
99 Return and discard changes
Enter desired menu number>
Path: 2 Configuration
2 Time handling
2 Time adjustment setting
1. Adjust mode:
0=time is slowly adjusted
1=time is set immediately
Notice:
This device supports “adjustment” only, therefore parameter is not
configurable
2. Maximum catch up speed
3. Time core type:
Standard=0 (0-255)
unused parameter
4. Synch. only offset:
0=off
1’000-5’000’000ns=Limits as from which time is no longer
accepted
Alarm “Synch only diff too large“
5. RTC mode
0=RTC deactivated
1=ON
Important!
The RTC mode is used only for test purposes!
RTC behaviour if mode=ON:
- A Valid time source has to be available for RTC first time set
- On startup the RTC is used to set the DTS time.
- As soon as an other source is available the DTS swiches to this source
- A time jump has be expectet on such source switch
Important!
For the
high precision time signal outputs
(1PPS, 10MHz, ToD,...), the
RTC mode should never be switched on!
Important!
RTC cannot handle Leap second
For a description of time-keeping see chapter “8 Time administration“