Operation
The junction box should be mounted in such a way that simple
wiring to the controller and the sensors is possible. The
connections for the sensors should always point downwards so
that no water can penetrate into the junction box. Inputs which
are not required must be sealed with dust protection caps.
Initially connect the digital controller to the input of the
distribution box.
Then connect the desired sensor combination, as shown
schematically below, at the outputs of the junction box. Allowing
for the moving direction, the front sensor will be connected to
output 1, the centre sensor at output 2 and the rear to output 3.
This sequence also applies for the numeric represen tation in the
display of the controller for the sensor ID.
On Positions 1 and 3 - i.e. front and rear - only ultrasonic sensors
may be implemented.