MLiS-S4101 Manual
18
6.24 Connection At
When the Connection Mode field is set to Client or Client (no heartbeat), this field becomes active, allowing the MLB-
S4101 (acting as a client) to connect to the server either on Power up or on Data Arrival (first character arriving).
6.25 Maximum Connection
This field allows the user to configure the Serial Server to have up to eight TCP connections.
6.26 Remote IP Address
This is a security feature that is activated when the IP address of the desired client is programmed into the remote IP
Address setting of the menu. This tells the MLB-S4101 to communicate with only the listed IP address and to filter out all
other requests for connection. The MLB-S4101 is setup in the menu as a TCP or UDP server to us this feature.
The default setting is 255.255.255.255. It is recommended not to change this setting until the application has been tested
and is communicating properly. At that point the address filtering feature of the MLB-S4101 can be activated.
6.27 Update/Save
Server properties must be updated separately for each serial port. Updating varies slightly depending on which of the four
configuration user interfaces are used.
6.27.1 Updating the Server Properties in Manager Software
From the Server Properties screen, click the Update button to store the configuration settings for the currently selected
port. The vcomui dialogue box will appear indicating you must restart the device before the new settings will take effect.
Click Yes.