6.15 Protocol
Select TCP or UDP protocol. If the application does not require a UDP connection, select TCP. TCP guarantees reliable
communication with error checking whereas UDP provides faster transmission.
When UDP mode is chosen the
Serial timeout
,
TCP alive timeout
,
Connection mode
,
Connection at
,
Maximum connection
and
Remote IP address
fields are replaced with the following three fields
: Destination IP address range
,
Port number
and
Source IP address range
. In this mode the server can be configured to broadcast data to and receive data from multiple
IP addresses. Four IP address range fields are provided.
6.16 Serial Timeout
Default is 0, or no timeout. Setting timeout to any value between 1 and 65535 seconds activates it. If communications are
idle for specified timeout value the serial server will reset and make itself available for another connection.
6.17 TCP Alive Timeout
This monitors TCP activity. If TCP activity stops for the length of time specified in this field the connection will be closed.
This field can be set to any value between 0 and 255 minutes. If zero, or no value, is entered into this field the server will
not disconnect.