MLiS-S4101 Manual
15
6.5 IP Address
A static IP address can also be assigned in this section of the menu. A dynamic address assigned by the DHCP server
may change if the MLB-S4101 loses the Ethernet connection or power is removed. The host (client) communication
software requests a connection to the specific IP address of the serial server. If the DHCP reassigns a different IP
address the software will not be able to communicate with the hardware. It is recommended to use a static IP address.
A static IP address is permanent and will not change unless changed in the menu. In most cases the network
administrator establishes the static address to be used.
6.6 Netmask
The default LAN netmask is configured for a Class C address. This maybe reconfigured by the user.
6.7 Gateway
The gateway IP address allows users to access the serial server from outside the LAN.
6.8 MAC Address
The MAC address is not adjustable. This is assigned in the factory. Every Ethernet device manufactured has it own
unique MAC address.
6.9 Version & Date
The currently loaded version of the firmware, and when it was released, are shown here.
6.10 Link Status
Link status automatically displays the type of Ethernet connection. It will either display 10 BaseT or 100BaseTX in full
duplex or half duplex. This will depend on the LAN, switches, hubs used in the LAN topology.
6.11 Server Serial Port
This field indicates the number of the port for with serial server properties are currently being displayed. Changing the
number in this field will cause all the other fields to display the properties for the specified port. Note, however, that before
changing ports, any change to properties must be Updated (Saved) or the serial server will not retain them.
6.12 Baud Rate
The serial port baud rate on the MLB-S4101 must match the serial baud rate of the connected device unless using Virtual
COM mode. In Virtual COM mode the software program will establish serial settings.
6.13 Data/Parity/Stop
This setting will have to match the data format of the connected device unless using Virtual COM mode. In Virtual COM
mode the software program will establish serial settings.
6.14 Flow Control
The flow control setting must match the connected serial device unless using Virtual COM mode. In Virtual COM mode
the software program will establish serial settings.