3.6  Dip Switches  

 
A double DIP switch allows theMLB-S4101 to be placed into Console/Loop back/Default/Data Mode.  
 

SW1  SW2  Mode  

ON 

ON 

Console 

ON 

OFF 

Loop back  

OFF 

ON 

Factory  

OFF 

OFF 

Data  

 
When all these switches are moved into the ON position, theMLB-S4101 enters Console Mode, allowing configuration of 
theMLB-S4101 from a PC running a terminal program such as Hyperterminal. When theMLB-S4101 enters Console Mode, 
the Console Mode screen will appear in the Hyperterminal program window. The serial port settings must be 8-N-1 at 
9600 baud. 
 
When the DIP switches are switched to the ON OFF position, the MLB-S4101 will work at Loop back Mode, all data is 
sent back immediately. 
 
When the DIP switches are switched to the OFF ON position, the MLB-S4101 will revert to its factory version firmware no 
matter what newer firmware has been upgraded. 
 
When all of the DIP switches are switched back to the OFF position, the MLB-S4101 will enter Data Mode (RS-232, RS-
422 or RS-485). 
 

3.7  Serial Ports 

 
The MLiS-S4101 has one serial port. The port can be configured as a Console Mode connection or as RS-232, RS-422 or 
RS-485 interface to the MLiS-S4101 (if all of the DIP switches are in the OFF position) using the Manager software, via 
Telnet, or using the Web Server. 
 
The RS-232 interfaces are configured as DTEs (Data Terminal Equipment). The connectors for all ports are DB-9M. 
 

3.8  Serial Server/Port Operational Modes 

 
Using the Manager software, the MLB-S4101 serial server can be put into Console Mode, Default Mode or Upgrade Mode. 
The serial ports can be configured for RS-232, RS-422 or RS-485 operation. The MLB-S4101 serial server also can be 
put into Console Mode by placing all the DIP switches into the ON position. 
 

3.8.1  Console Mode 

 
The console mode allows access to the MLB-S4101 setup menu. This is one way to reconfigure the default settings for 
the application. A serial connection is made between a COM port on the PC and the MLB-S4101 serial port 1 with a null 
modem cable. In console mode, the serial port defaults to an RS-232 interface.  
 
The MLB-S4101 serial port default settings are, baud rate 9600, 8 data bits, no parity, and 1 stop bit. Hyper Terminal 
should be used for this type of setup. Hyper Terminal’s serial settings are configured the same as the mentioned default 
settings of the MLB-S4101 and must be set to VT100 emulation mode. The default settings are used only if they have not 
been changed. 
 
See Chapter 10 for details.  

 

3.8.2  Upgrade Mode 

 
The newest firmware can be installed on the MLB-S4101 

using the PC’s serial port or the Virtual COM port.   

 
See Chapter 13 for details. 

Содержание MLB-S4101

Страница 1: ...MLiS S4101 Manual MLB S4101 Ethernet Serial Server USER MANNUAL...

Страница 2: ......

Страница 3: ...4 RS 232 Mode 8 3 8 5 RS 422 Mode 8 3 8 6 RS 485 Mode 8 3 9 DB9 PIN CONFIGURATION 8 4 MLB S4101 SOFTWARE INSTALLATION 9 4 1 NEW INSTALLATION 9 4 2 UPDATING AN EXISTING INSTALLATION 11 5 USING MANAGER...

Страница 4: ...ta in Console Mode or Telnet 19 6 27 3 Web Server Interface 20 7 INSTALLING VIRTUAL COM PORT 21 8 CONFIGURING VIRTUAL COM PORT 23 8 1 CONFIGURATION WITH MANAGER SOFTWARE 23 8 2 CONFIGURATION WITH DEVI...

Страница 5: ...s in the Device Manager of the operating system The virtual COM port is designed to establish a connection with the MLB S4101 This in turn will allow communications with the connected serial device in...

Страница 6: ...n odd mark space Data Bits 5 6 7 or 8 Stop Bits 1 1 5 or 2 Protocol TCP IP ARP DHCP Telnet HTTP UDP ICMP Management Manager software Serial Console Telnet Web server Firmware upgradeable Operating Tem...

Страница 7: ...ee bottom label Version Date current firmware version number and date Serial port 1 Baud rate 9600 Data Stop bits 8 1 Parity None Flow control None Protocol TCP Serial timeout 0 seconds TCP alive time...

Страница 8: ...4101 when the program opens the virtual COM port Once the connection is made the LAN is transparent to the serial device Applications work just as if the serial device is connected a host s physical C...

Страница 9: ...to reconnect without personally attending to the problem A TCP data connection can be lost when there is a power failure or temporary loss of an Ethernet connection on either the client or server If a...

Страница 10: ...ock or the power jack It accepts 9VDC 15VDC 500mA power supply When power is apply a green light label as run will flash every one second to indicate the system is up and running 3 3 Ethernet Connecti...

Страница 11: ...tion using the Manager software via Telnet or using the Web Server The RS 232 interfaces are configured as DTEs Data Terminal Equipment The connectors for all ports are DB 9M 3 8 Serial Server Port Op...

Страница 12: ...are in differential pairs Ground provides a common mode reference To use handshaking Flow Control must be set to RTS CTS during configuration Refer to the Pin out table for connections 3 8 6 RS 485 Mo...

Страница 13: ...with the available setup menu in the Manager software 4 1 New Installation The following procedure installs the MLB S4101 Manager software 1 Inserting the MLB S4101 CD in the CD ROM will automatically...

Страница 14: ...tall Shield Wizard Complete screen appears When the installation is complete the Install window closes allowing the user to access the Manager software in the program files If loaded in the default lo...

Страница 15: ...of the Manager software is already installed the Modify repair or remove the program window will appear when the installation process is initiated The recommended procedure is to remove all installed...

Страница 16: ...ect MLB S4101 Manager in the program file menu If the default location was selected during the installation the program will be found under Start Programs MLiS Select MLiS S4101 Manager As soon as the...

Страница 17: ...window The Server Properties window is used to configure and store the Server configuration settings Details for setting Properties are described in the next chapter 3 After configuring as needed cli...

Страница 18: ...Number Each MLB S4101 has a unique serial number This is fixed and cannot be changed 6 3 Password Entering a password activates a security feature on the serial server Once a password is entered it wi...

Страница 19: ...f the firmware and when it was released are shown here 6 10 Link Status Link status automatically displays the type of Ethernet connection It will either display 10 BaseT or 100BaseTX in full duplex o...

Страница 20: ...his mode the server can be configured to broadcast data to and receive data from multiple IP addresses Four IP address range fields are provided 6 16 Serial Timeout Default is 0 or no timeout Setting...

Страница 21: ...P protocol will pack the data currently in the serial buffer into a packet and send it out the Ethernet port 6 21 Port Status This field indicates whether a serial port is connected to a server or by...

Страница 22: ...lter out all other requests for connection The MLB S4101 is setup in the menu as a TCP or UDP server to us this feature The default setting is 255 255 255 255 It is recommended not to change this sett...

Страница 23: ...r options shown on the right side of the Configuration screen Save Default Running and Reset Use Tab Backspace or arrow keys to move the cursor to the option position then press Enter Save stores the...

Страница 24: ...The Web Server interface provides the same updating options as Console Mode and Telnet These are located at the bottom of all three Web Server pages If a field is changed you must click Save before l...

Страница 25: ...tware used in most applications allowing the software to open a connection with the serial port located anywhere on the LAN When using the virtual COM port the MLB S4101 is configured as a TCP or UDP...

Страница 26: ...ngs in the MLB S4101 The settings of the Virtual COM port in the Device Manager and the MLB S4101 Configuration menu must match If the settings do not the software connecting to the Virtual COM port w...

Страница 27: ...ol and Flow Control settings must match the MLB S4101 settings for the software to open the Virtual COM port 8 1 Configuration with Manager Software 1 At the Desk Top select Start Programs MLiS MLB S4...

Страница 28: ...trol Panel window opens 2 In the System Properties window select the Device Manager button 3 In the Device Manager select the button next to Ports COM LPT to expand and see the ESport COM Double click...

Страница 29: ...of Windows 98 ME NT 2000 and XP Windows 98 users will also find a Remove Virtual COM feature in the programs file 9 1 Removing the Virtual COM port with Manager Software 1 At the Desk Top select Start...

Страница 30: ...Manager window opens 2 Select Device Manager in the Systems Properties window In the Device Manger window select the next to Ports COM LPT to expand 3 Highlight ESport COM to be removed go the Action...

Страница 31: ...Data bits 8 Parity None Stop bits 1 and Flow control None Ensure all the DIP switches are in the ON position for MLiS S4101 To view the menu hit the space bar There are six Console Mode screens Server...

Страница 32: ...MLiS S4101 Manual 28...

Страница 33: ...MLiS S4101 Manual 29...

Страница 34: ...al 30 Once all the changes have been made move to the Configuration screen select Save and press Enter The restart message will appear Select Yes to save changes This is necessary to write the setting...

Страница 35: ...n Server Properties Ensure the PC and MLB S4101 are connected to the LAN and the serial server is in RS 232 RS 422 or RS 485 mode before you can telnet to it and access the configuration screens From...

Страница 36: ...s See chapter 6 for details on Server Properties In Internet Explorer type the IP Address of the Serial Server into the address field near the top of the window and press the Enter key The following w...

Страница 37: ...MLiS S4101 Manual 33 To change other operational properties click Operation on the left side of the browser window The following page will appear...

Страница 38: ...MLiS S4101 Manual 34 Click Save to store changes to the Serial Server Settings for each Port must be saved separately...

Страница 39: ...01 When using the Virtual COM mode a cable is not required 4 Open the Manager software and select the Firmware Upgrade button 5 In the Serial Port selection options select the COM port number used to...

Страница 40: ...ow control mode are the same and the remote IP address should be the host IP address Besides the MLB S4101 cannot be at Console mode Q Why the arrow keys of hyperterminal in Windows 2000 do not work i...

Страница 41: ...MLiS S4101 Manual 37...

Страница 42: ...2502 5095 China 86 755 8376 0232 Singapore 65 6272 7233 Email sales mlis schmidtelectronics com Official Website MLiS Website www schmidtm2m com Support www schmidtm2m com support Download www schmidt...

Отзывы: