background image

 

MLB-S-BGS2-BW Terminal User Guide 

Rev 1.3  

 

 

MLB-S-BGS2-BW Terminal 

User Guide 

 

MLiS Basic Dual / Quad Band GSM/GPRS 

Model Number:  

MLB-S-BGS2-BW 

 

 

Содержание MLB-S-BGS2-BW

Страница 1: ...MLB S BGS2 BW Terminal User Guide 1 Rev 1 3 MLB S BGS2 BW Terminal User Guide MLiS Basic Dual Quad Band GSM GPRS Model Number MLB S BGS2 BW...

Страница 2: ...t to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical including but not limited to photocopying recording transmitti...

Страница 3: ...Terminal User Guide 3 Rev 1 3 Revision History Version Date Description 1 0 Jan 2013 1st Release 1 1 Mar 2013 2nd Modify Power supply 1 2 Sep 2013 3rd Keep MLB S BGS2 BW only 1 3 Apr 2014 4rd New Comm...

Страница 4: ...2 MECHANICAL DESCRIPTION 13 2 1 Overview 13 2 2 Dimensions 13 3 ELECTRICAL INTERFACE DESCRIPTIONS 14 3 1 Overview 14 3 2 Radio Interface Type SMA Connector Female RF Antenna 15 3 3 RJ45 Connector 15 3...

Страница 5: ...POP3 Mode 30 5 9 Command Explanation 32 5 9 1 AT SICS Internet Connection Setup 32 5 9 2 AT SISS Internet Service Setup 35 5 9 3 AT SISO Internet Service Open 47 5 9 4 AT SIST Enter Transparent Access...

Страница 6: ...Holder for MLB S BGS2 BW 18 Figure 8 LED indication for MLB S BGS2 BW 19 List of Tables Table 1 Operating Modes 10 Table 2 Features and Specifications 12 Table 3 Chassis Dimensions and Mechanical Desc...

Страница 7: ...o provide a wireless communications link for many applications including metering fleet and asset management vending security and alarm monitoring e maintenance and other telemetry applications 1 2 Hi...

Страница 8: ...ta Transmission GPRS Class 12 max 86kbps DL UL Mobile station class B PBCCH support Coding schemes CS 1 4 CSD Data Transmission Up to 14 4kbit s V 110 RLP Non transparent USSD support PPP stack for GP...

Страница 9: ...connector The remaining RJ45 connector pins are used for data communications The SMA female connector provides the air interface to an external 50 ohm antenna specified for the correct frequency band...

Страница 10: ...g multislot settings GPRS DATA GPRS data transfer in progress Power consumption depends on network settings e g power control level uplink downlink data rates GPRS configuration e g used multislot se...

Страница 11: ...6kbps Downlink and Uplink Full PBCCH Support Mobile Station Class B Coding Scheme 1 4 PPP stack CSD V 110 RLP non transparent 2 4 4 8 9 6 14 4kbps USSD PPP stack for GPRS data transfer 8 SMS Point to...

Страница 12: ...T SMSO 19 RoHs All hardware components are fully compliant with the EU RoHs directive 2002 95 EC Exception MLB55IN Table 2 Features and Specifications 1 5 Precautions The MLB S BGS2 BW terminal is des...

Страница 13: ...ong with the positions of the different connectors The terminal case is made of durable plastic 2 2 Dimensions Figure 2 Chassis Dimension for MLB S BGS2 BW S N Parameter Value 1 Height H 22 mm 2 Lengt...

Страница 14: ...io Interface RF Connector SMA Female Connects to external 50 ohms antenna of correct frequency band 2 RJ45 Connector For Power and Communications 3 Power Status LED Indicator LED lights up when power...

Страница 15: ...general the RG174 or RG58 50 ohms types should be good for normal use Avoid excessive cable length of 10 metres Compatible RF antennas PCB patched or Monopole type are available for order please refer...

Страница 16: ...Send 3 CTS I Clear to Send 4 RxD I Receive Data 5 TxD O Transmit Data 6 GND Ground 7 DTR I Data terminal ready 8 DSR O Data Set Ready Table 5 RJ45 connector configuration for MLB S BGS2 BW 3 4 Operati...

Страница 17: ...he possible patterns of status LED behavior and describes the terminal operating status indicated by each pattern if AT SSYNC parameter mode 1 To better monitor the operating states while power saving...

Страница 18: ...ked It can be accessed through removing the battery cover as shown below Figure 7 SIM Card Holder for MLB S BGS2 BW Be sure to power off modem when you replace the SIM card Otherwise it may cause dama...

Страница 19: ...ere are 2 ways to switch off power down the modem as described below a The AT SMSO command lets the MLB S BGS2 BW terminal log off from the network and allows the software to enter into a secure state...

Страница 20: ...F 1 ok AT CMGS Number key in Text ctrl z End Send SMS connection Text Start AT CPMS MT MT MT ok ok ok AT CNMI 1 1 AT CMGF 0 ok AT CMGS Length key in PDU ctrl z End Send SMS connection PDU Start AT CPM...

Страница 21: ...used2 total2 used3 total3 mem1 str Memory to be used when listing reading and deleting messages SM SIM message storage ME Mobile Equipment message storage MT D Sum of SM and ME storages mem2 str Memor...

Страница 22: ...sages currently in mem2 used3 num Number of messages currently in mem3 total1 num Number of messages storable in mem1 total2 num Number of messages storable in mem2 total3 num Number of messages stora...

Страница 23: ...al User Guide 23 Rev 1 3 New SMS View AT CNMI New short Message Indication AT CNMI 1 1 AT CMGR Read SMS messages AT CMGR 1 AT CMGL List SMS messages from preferred store AT CMGL ALL AT CMGD Delete sho...

Страница 24: ...onType GPRS0 AT SICS 0 apn internet AT SISS 1 srvType Socket ok AT SISS 1 conId 0 AT SISS 1 address socktcp 175 180 133 126 3001 AT SISO 1 Internet Service Open SISW 1 1 service is ready for upload AT...

Страница 25: ...AT SISS 1 conId 1 AT SISS 1 address 175 180 133 126 7300 time 200 Transparent mode connection Start AT SISO 1 Internet Service Open SISW 1 1 service is ready for upload AT SIST 1 Enter Transparent Acc...

Страница 26: ...AT SISS 1 alphabet 1 ok AT SISO 1 Internet Service Open AT SISW 1 reqWriteLength Service Write Data AT SISR 1 reqReadLength Internet Service Read Data AT SISC 1 Internet Service Close ok ok ok ok AT S...

Страница 27: ...tp 175 180 133 126 8080 Peter test txt End HTTP POST connection Start AT SISS 1 hcMethod 1 ok AT SISS 1 hcContLen 150 ok ok ok ok AT SICS 0 conType GPRS0 AT SICS 0 apn internet AT SISS 1 srvType Http...

Страница 28: ...om OK AT SISS 1 smSubj Meeting Request Sunday Morning OK AT SISS 1 smAuth 1 OK AT SISO 1 OK Select connection type GPRS0 APN to access the GPRS services provided by the internet Select service type SM...

Страница 29: ...Morning everyone we are delighted to announce our next meeting on Sunday morning OK AT SISC 1 OK Service is ready for upload The email to be sent has 87 bytes The write command response confirms that...

Страница 30: ...Select connection type GPRS0 APN to access the GPRS services provided by the internet Select service type POP3 Select connection profile 0 Specify POP3 server address Specify recipient s mailbox name...

Страница 31: ...ubscriber1 testdomain com Subject TestMail Message Id 20051220070007 379321D004 testdomain com Date Tue 20 Dec 2005 08 00 07 0100 Ok AT SISR 1 500 AT SISR 1 78 CET X UIDL lL Z6 cl 1 Status RO Hallo To...

Страница 32: ...ecific profile This means that different profiles may use different alphabets Unlike other parameters the alphabet can be changed no matter whether the conParmTag value conType has been set For suppor...

Страница 33: ...be ignored Otherwise this value can be used to manually configure an alternate server for the DNS1 If dns1 is not equal 0 0 0 0 and no dns2 address is given then dns2 0 0 0 0 will be assumed automatic...

Страница 34: ...Type mandatory mandatory user optional optional passwd optional optional apn optional inactTO optional optional calledNum mandatory dataType mandatory dns1 optional optional dns2 optional optional alp...

Страница 35: ...ecutive usage of AT SISS For supported values of srvParmValue refer to srvParmValue srv Type alphabet Selects the character set for input and output of string parameters within a profile The selected...

Страница 36: ...licable 3 FTP Not applicable set within address parameter 4 HTTP Length 2 31 Password for the HTTP authentication mechanism Currently HTTP simple authentication is supported only 5 SMTP Password to be...

Страница 37: ...h 0 216 1 If this parameter is not set SMTP default port number 25 is used 6 POP3 POP3 server TCP port number numeric Length 0 216 1 If this parameter is not set POP3 default port number 110 is used a...

Страница 38: ...mode range 20 100 500 milliseconds in steps of 20 etx Specifies the character used to change from transparent access mode to AT command mode range 1 15 17 255 16 is not allowed because it is used as D...

Страница 39: ...for Transparent TCP Listener service only It is possible to specify a maximum of 3 filters separated by commas Each filter is specified as 4 numbers separated by dots n n n n Each number n can be in...

Страница 40: ...e Unique command to create a file name unique to the current directory If the file name is assigned by the server then the SIS URC will appear indicating urcInfoId 2100 and the file name d elete clear...

Страница 41: ...C SISW x 1 then the AT SISW write command can be executed After the exact number of bytes are transferred via the serial interface the HTTP client will go from service state Up to service state Closin...

Страница 42: ...parate individual address values e g john smith somedo main de tom meier somedomain de Some mail servers do not accept recip ient addresses without brackets It is recommended to use the RCPT TO variab...

Страница 43: ...used to specify the length of the message s to be retrieved from or deleted on the POP3 server If no specific value is set in the service profile the default value 0 is assumed which means that there...

Страница 44: ...s described for tcpOt Setting is not relevant for Internet Service Socket with type UDP secOpt Parameter for secure connection TLS settings for following services TCP Socket client Transparent TCP cli...

Страница 45: ...ated srvParmTag srvParmValue srvType str Supported Internet service type values in srvParmValue for srvParmTag value srvType Before changing the srvType of an existing service profile be sure that the...

Страница 46: ...ting as FTP client Http MLB S BGS2 BW acting as HTTP client Smtp MLB S BGS2 BW acting as SMTP client Pop3 MLB S BGS2 BW acting as POP3 client none Reset Internet service profile settings Operation is...

Страница 47: ...IST srvProfileId srvProfileId num srvProfileId 0 9 specified with AT SISS 5 8 5 Escape from Data Mode to AT Command Mode esacape sequence is only available during a CSD call or a GPRS connection The c...

Страница 48: ...he amount of data already sent with AT SISW but not yet acknowledged Parameter reqWriteLength may be 1 1500 bytes to specify the amount of data to be sent with AT SISW If parameter reqWriteLength equa...

Страница 49: ...e greater than 0 though it is not necessary to specify the precise number of bytes In this case the cnfWriteLength parameter indicates the maximum length of the data stream without control character C...

Страница 50: ...ls 0 all data sent so far is acknowledged In binary mode unackData includes the cnfWriteLength value of the pending write operation There fore the very first write operation of an upload job returns i...

Страница 51: ...Peek Operator Query number of received bytes within internal buffers The behaviour of the peek operator depends on the selected Internet service i e it may not be supported by all IP Services For Soc...

Страница 52: ...imum packet size of 1500 bytes To compensate this the host is advised to request via reqReadLength an amount less or equal its maxmimum buffer capacity and wait for the resulting AT SISR write command...

Страница 53: ...7956 8670 E info kl schmidtelectronics com Shenzhen China Schmidt Co China Ltd Shenzhen Branch Schmidt Shenzhen Co Ltd 3 F Unit E International Culture Building Fu Tian Road Shenzhen 518033 T 86 755 8...

Страница 54: ...nnection and SMS Power Adaptor MLA PSP 100 Input AC 100 240V Output 9V 1 3A DC Jack 5 5 2 1 MLA PSP 101 US Adapter Plug MLA PSP 104 British Adapter Plug MLA PSP 103 European Adapter Plug MLA PSP 102 A...

Страница 55: ...MLB S BGS2 BW Terminal User Guide 55 Rev 1 3 Notes...

Страница 56: ...MLB S BGS2 BW Terminal User Guide 56 Rev 1 3...

Отзывы: