INSTALLATION

Note - If this luminaire is being used in conjunction with an external PIR or sensor, please 
confirm with the manufacturer of the sensors that they are compatible with LED luminaires. 
• Provide power to the required point of installation  
• Remove the front plate by placing a medium size flat-head screwdriver in the notch on 
the side and lever off gently (see Fig. 1) 

Fig. 1

INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following product

s

NH023AW / NH023B / NH025AW 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of 

the circuit cable, fuse, or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product is for indoor use only 

 

This product is Class I and must be earthed 

 

This product is IP20 rated 

INSTALLATION 
Note -

 If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the 

manufacturer of the sensors that they are compatible with LED luminaires. 

 

Provide power to the required point of installation  

 

Remove the front plate by placing a medium size flat-head screwdriver in the notch on the side and 

lever off gently (see Fig. 1) 

 

 

 

 

 

 

Fig. 1 

 

 

 

 

 

 

 

Connect the luminaire to the mains supply ensuring the correct polarity is observed: L 

 Live (brown), 

 Earth (green/yellow), N 

 Neutral (blue) 

 

All earth connections must be made and maintained. Use green/yellow sleeving on earth conductors 

that are not insulated 

 

Check all electrical connections are secure with no loose strands of cable 

 

Fit the unit into a suitable wall box taking care not to compress, damage, or trap any cables, and 

secure with the screws provided 

 

Clip the front plate onto the main assembly ensuring the screwdriver notch is at the side 

 

Switch on and check for correct operation 

 