ToolLink User Manual
MKS Instruments, Inc.
Page 18 of 30
MACID – Attribute 1
The MACID is set using two BCD rotary switches located on the front panel. Valid MACID addresses are 0 to
63 (0 to 3F Hex). Setting the switch address to a value greater than 63 will disable the switch and allow
software setting of the MACID. The software setting defaults to the last hardware setting. The switch is only
read during power up.
Baud Rate – Attribute 2
Settable only if the Baud Rate switch is set to a value greater than 2. Value returned will be switch value if
less than 4 or the last value set.
Switch/Value
Speed
52 125 kbits
52 250
kbits
52 500
kbits
52 Software
settable
Allocation Information – Attribute 5
Allocation_byte
bit 0
explicit set to 1 to allocate
bit 1
polled set to 1 to allocate
bit
2
strobed
(not
supported)
bit 3-7 reserved (always 0)
Assembly Object
Class Code: 04 (0x04)
The Assembly Objects bind attributes of multiple objects to allow data to or from each object to be sent or
received over a single connection.
Table 11
Class Attributes
Attribute Access Name
Type
Value
1 Get
Revision
UINT
2
2 Get
Max
Instance
UINT
102
Table 12
Instance 101 Attributes
Attribute Access Name
Type
Value
3
Get
Data Stream (Input)
see notes
(1)
Table 13
Instance 102 Attributes
Attribute Access Name
Type
Value
3
Get/Set
Data Stream (Output)
see notes
(2)