ToolLink User Manual
MKS Instruments, Inc.
Page 20 of 30
Table 17
Instance 2 Attributes (POLL connection)
Attribute Access Name
Type
Value
1 Get
State
USINT
See
Below
2
Get
Instance Type
USINT
1 = I/O Message
3
Get
Transport Class Trigger
USINT
0x83
4 Get
Production
Connection
UINT
See
Below
5 Get
Consumed
Connection
UINT
See
Below
6 Get
Initial
Comm.
Char.
USINT
0x01
7 Get
Production
Size UINT
See
Below
8 Get
Consumed
Size UINT
See
Below
9
Get/Set
Expected Packet Rate
UINT
default 2500 msec
12
Get/Set
Timeout Action
USINT
See Below
13
Get
Prod. Path Length
USINT
See Below
14
Get/Set
Production Path
STRUCT of
Log. Seg., Class
USINT
0x20
Class Number
USINT
0x04
Log.Seg., Instance
USINT
0x24
Instance Number
USINT
0x100 (default)
Log.Seg., Attribute
USINT
0x30
Attribute Number
USINT
0x03
15 Get
Cons.
Path
Length
USINT3
6
16
Get/Set
Consume Path
STRUCT of
Log. Seg., Class
USINT
0x20
Class Number
USINT
0x04
Log.Seg., Instance
USINT
0x24
Instance Number
USINT
0x101 (default)
Log.Seg., Attribute
USINT
0x30
Attribute Number
USINT
0x03
Table 18
Common Services
Service Code
Class
Instance
Service Name
05 (0x05)
No
Yes
Reset
14 (0x0E)
Yes
Yes
Get_Attribute_Single
16 (0x10)
No
Yes
Set_Attribute_Single
State – Attribute 1
Connection States:
0
=
non-existent
1
=
configuring
3
=
established
4
=
timed
out
Connection ID’s – Attributes 4 and 5
Connection 1 Produced Connection ID: 10xxxxxx011
Connection 1 Consumed Connection ID: 10xxxxxx100
Connection 2 Produced Connection ID: 01111xxxxxx