4.

 

How to Operate the Front Keys 

All settings are done by means of two front keys. A third key on the utmost right side of the 
panel is reserved for special key operations, but not in use with standard AX346 units. 

 

 

ENTER key: scrolls through the menu headlines. 

 

 

SET key: selects the actual menu and allows to choose the desired setting or to adjust 

the desired numeric value of the actual parameter. 

 

 

ENTER key: confirms and stores the actual parameter choice and changes over to the 
next menu item. 

 

 

Key reserved for spezial operations (not in use with standard AX346 units) 

 

 

To start the menu dialogue, please keep ENTER down for at least 3 seconds. 

 

With numerical entries, at first the lowest digit will blink. When keeping the SET key down, the 
highlighted digit will scroll in a continuous loop from 0 … 9 … 0 … 9. When you release the 

SET key, the actual digit will remain and the next digit will be highlighted (blink). This 
procedure allows to set all digits to the desired values. After the most significant digit has been 
set, the low order digit will blink again and you can do corrections if necessary. With signed 

parameters, the high order digit will only scroll between the values “0” (positive) and “-“ 
(negative) To store the actual setting, press the ENTER key, which will also automatically scroll 
forward the menu. 

 

The unit changes from programming mode to normal operation when you keep down the ENTER 

key again for at least 3 seconds. 

 

Furthermore a “time-out” function will automatically conclude every menu level, when for a 
break period of 10 seconds no key has been touched. In this case, any entry which has not been 
confirmed by ENTER yet would remain unconsidered. 

 

At any time it is possible to Reset all parameters to the Factory Default Settings 

 

To do this, power the unit down, and keep the ENTER key down while you power the unit up 

again. This will set the unit to the factory default state. See the parameter default values from 
the parameter list at the end of this manual. 
 

«

™

)

«

Содержание AX346

Страница 1: ...oder 0 4 20 mA with individual scaling Operation modes to display input A input B or combined values A B A B AxB and A B Selectable linearisation function with 16 interpolation points Adjustable analo...

Страница 2: ...s a must to observe all general and also all country specific and application specific safety standards When this unit is used with applications where failure or maloperation could cause damage to a m...

Страница 3: ...ic Set Up and Operational Parameters 10 5 1 Basic Set Up 10 5 2 Operational Parameters 11 5 2 1 Operational parameters with single channel mode 11 5 2 2 Operational parameters with dual channel mode 1...

Страница 4: ...of the possibilities to calculate combined values like difference or ratio of the two inputs and by the in built facility of programmable linearisation this unit is also suitable to operate as a signa...

Страница 5: ...provide DC supply from a 17 to 30 volts DC power unit The current consumption depends on the level of the input voltage and is typically 130 mA with 17 volts and 80 mA with 30 volts sensor current tak...

Страница 6: ...nputs 2 4 Adjustable Analogue Output The unit provides a voltage output with ranges 0 10 volts or 10 to 10 volts output current max 2 mA and a current output 0 4 20 mA external load 0 300 Ohms The res...

Страница 7: ...20 mA there is no need to change any jumper settings and you may skip this section Where however one or both inputs should be used for voltage it is necessary to set the jumpers as shown below To acce...

Страница 8: ...oltage range you can modify the corresponding input to accept voltages up to 120 volts by adding a serial resistor to the input terminal please observe safety standards The subsequent formula shows ho...

Страница 9: ...e next digit will be highlighted blink This procedure allows to set all digits to the desired values After the most significant digit has been set the low order digit will blink again and you can do c...

Страница 10: ...nput A and input B separately A u B Summing mode input A input B A B Differential mode input A input B A d B Ratio mode input A input B A m B Multiply mode input A x input B Bright Brightness of displ...

Страница 11: ...every menu and are absolutely identical with all modes Therefore these parameters are described only once and separately under section 5 2 4 To exit the parameter menu you can either press the ENTER...

Страница 12: ...tely A LED bar in the most significant decade of the display indicates if your actual reading is channel A or channel B Menu Selection Text Description Input A Input range channel A in U Voltage input...

Страница 13: ...isplay Choose from the formats shown in the display 5 2 3 Operational parameters for the combined modes A B A B AxB A B This mode provides the possibility to display the single channel results A or B...

Страница 14: ...he analogue output depends only from the value shown in the display of the unit and from the scaling parameters shown below Therefore the analogue signal would also contain possible combinations and c...

Страница 15: ...s This means e g that the unit will replace the previous P02_x value by the new P02_y value x registers have to use continuously increasing values e g the lowest display value must be set to register...

Страница 16: ...following picture explains the difference between the linearisation modes 1_quA und 4_quA x y P1 x 0 P1 y 0 Linearisation Mode 1_quA x y Linearisation Mode 4_quA P1 x 1000 P1 y 900 P8 x 0 P8 y 750 P1...

Страница 17: ...ingle mode Dual mode Combined modes Linearisation modE inPutA inPutA inPutA briGht StArtA StArtA StArtA UPdAt End A End A End A CodE dPoi A dPoi A dPoi A LinEAr FiLt A FiLt A FiLt A A CHAr inPutb inPu...

Страница 18: ...Ax34601a_e_A5 doc Feb 06 Page 18 20 6 2 Dimensions 96 0 110 0 44 0 10 0 8 0 91 0 1 2 3 4 10 9 1 2 3 4 5 6 7 8 48 0 9 0 21 0 129 0 140 5 Panel cut out 91 x 44 mm...

Страница 19: ...ltage Ri 30 kOhms Resolution 14 bits 13 bit sign Accuracy 0 1 1 digit Analogue outputs 0 4 20mA max 300 Ohms 0 10V max 2 mA Ambient temperature 0 45 operation 25 70 storage Housing Norly UL94 V 0 Disp...

Страница 20: ...Filter A 0 4 1 1 09 Input Mode B 0 2 1 1 11 Start value B 99999 99999 0 5 12 End value B 99999 99999 1000 5 13 Decimal point B 0 5 0 1 15 Average filter B 0 4 0 1 14 Proportional Factor 10000 10000 1...

Отзывы: