![MKS AX346 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/mks/ax346/ax346_operating-instructions-manual_1813500012.webp)
Ax34601a_e_A5.doc / Feb-06
Page 12 / 20
Menu Selection
Text
Description
Filt A
Digital filter to smooth unsteady display caused by
ripple or fluctuation of the input signal.
OFF Filtering
off
2, 4, 8, 16 Filter with 2, 4, 8 or 16 floating average
determinations
dPoiA
Decimal point position of channel A display
Choose from the formats shown in the display
5.2.2.
Operational parameters with dual channel mode
With this mode the SET key provides a toggle function between channel A and channel B.
Both channels can be scaled fully separately.
A LED bar in the most significant decade of the display indicates if your actual reading is
channel A or channel B.
Menu
Selection
Text
Description
Input A
Input range channel A
in U
Voltage input 0 - +/-10 V
in i0
Current input 0 – 20 mA
in i4
Current input 4 – 20 mA
Start A
Start value which the unit will display with a zero
input signal of 0 volts or 0/4 mA
End A
End value which the unit will display with a full
scale input of 10 volts or 20 mA
Filt A
Digital filter to smooth unsteady display caused by
ripple or fluctuation of the input signal.
OFF Filtering
off
2, 4, 8, 16 Filter with 2, 4, 8 or 16 floating average
determinations
dPoiA
Decimal point position of channel A display
Choose from the formats shown in the display