Description of the unit
13
Installation instructions
3.3 Equipment and connection data
Model: FKECOD
Size
615
621
115
121
215
221
Dimensions
Unit
Length x Width x Height (mm)
997 x 799 x 790
997 x 799 x 1060
1075 x 813 x 1960
Weight
(kg) unit
120
125
140
145
305
313
Emissions
Latent heat (W)
1780*
3670*
2750*
5400*
5510*
10200
Sensible heat (W)
1190
2450
1840
3600
3670
7100
Noise level (db(A))
< 70
* The stated value is reduced by 80 % when operating with a condensation hood; the sensible heat is increased by the
amount of the reduction.
Operating environment
Temperature (°C)
5 — 40
Relative humidity (%)
Non-condensing
95
Power connection
Protection class
IPX5, IPX6 (optional)
Type of connection
3PE / AC 50/60 Hz, 3NPE / AC 50/60 Hz
Voltage (V)
200
Connected load (kW)
10.1
16.3
14.7
25.5
29.4
50.9
Fuse (A)
3 x 35
3 x 50
3 x 50
3 x 80
3 x 100
3 x 180
Voltage (V)
208
Connected load (kW)
10.2
17.4
15.7
27.3
31.4
54.6
Fuse (A)
3 x 35
3 x 50
3 x 50
3 x 80
3 x 100
3 x 180
Voltage (V)
220
Connected load (kW)
11.6
19.7
17.7
30.8
35.4
61.4
Fuse (A)
3 x 35
3 x 63
3 x 63
3 x 100
3 x 125
3 x 180
Voltage (V)
230
Connected load (kW)
12.6
21.4
19.3
33.6
38.6
67
Fuse (A)
3 x 35
3 x 63
3 x 63
3 x 100
3 x 125
3 x 180
Voltage (V)
240
Connected load (kW)
13.7
23.3
21
36.5
42
72.9
Fuse (A)
3 x 35
3 x 63
3 x 63
3 x 100
3 x 125
3 x 180
Voltage (V)
380
Connected load (kW)
9.4
18.9
14.4
27.6
28.7
55
Fuse (A)
3 x 16
3 x 35
3 x 25
3 x 50
3 x 50
3 x 100
10013865-0AIBE-B