Description of the unit
16
Installation instructions
Basic control setting
Basic setting
Parameter
s
Standard
value
Adjustment
range
Explanation
Date / time
yyyy - mm - dd
hh : mm
Year - Month - Day
Hour : Minute
Unit of temperature
1
°C
°C
Celsius (°C)
°F
Fahrenheit (°F)
Altitude
2
0 — 999
0 — 999 m
Request the altitude above sea level from
the local weather station. If the altitude is
unknown, set 0 – 999 m.
1000 m — 1999
m
2000 m — 2499
m
2500 m or higher
80 % power
3
100
80 %
Power can be limited to 80 % (for special
applications).
100 %
Actual voltage
14
400
100 — 500 V
Set the local, mean voltage between the
line conductors.
Audible signal
volume
33
Medium
Individual
Sets the volume.
Signal tones
Sound 1
Sound 1 — 4
There are 4 sets of different sounds
available.
Unit of volume
34
ml
(ml)
Millilitre (ml)
(fl.oz.)
Fluid ounce (fl.oz.)
35
Imperial
(fl.oz.)
Imperial (fl.oz.)
Imperial fluid ounce
U.S. (fl.oz.)
U.S. fluid ounce
Power optimisation
system
42
Off
On
If a power optimisation system is
connected, "On" must be selected for the
unit to heat.
Off
Water filter
maintenance
44
0
0 — 99900 l
Water quantity up to the maintenance
message.
0 = No maintenance message
Network
DHCP
Network address
and DHCP
Select and set interface.
Kitchen management
system
Disabled
Active
Disabled
Port and unit address can be set.
Ethernet
Ethernet
Serial
Type of signal transmission
Settings parameters
1. Set parameters via the roller.
2. Tap the "Read" button to display the
set value.
3. Specify another value via the button
panel.
4. Press the "Write" button to save the
new value.