MK-100
Revision 1/01, Effective Date January 23, 2001
Page 36
MAINTENANCE AND TROUBLESHOOTING
7. Blade Stops Turning:
(D)
Verify circuit breaker at least 20
amps – if not, move to 20-amp
circuit
(A)
Allow motor to cool and
depress motor Overload
Reset Switch
(F)
Check power source voltage is
115V – if not 115v, move to
another circuit
(B)
Verify all plugs fully installed
(C)
Check Ground Fault Circuit
Interrupter (GFCI) tripped
(E)
Verify circuit breaker not tripped
If tripped, reset once
Return to
MK Diamond
for Repair
(G)
Return to MK Diamond
If less than 20
Amps move saw
to 20 Amp circuit
Overload
Reset Switch
If motor does not
start, go to Step B
Verify all plugs
connected
If all plugs connected,
go to Step C
If not tripped, or
If re-trip occurs,
Go to Step D
Reset once
if tripped
If circuit 20 Amp
or greater
go to Step E
Check Breaker
20 Amps
or greater
If tripped, reset
once if trips again,
go to step F
If circuit breaker
not tripped
go to Step F
Check Breaker
tripped
If circuit breaker
not tripped
go to Step F
Check for
correct circuit
voltage