![MJK MagFlux Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/mjk/magflux/magflux_installation-and-user-manual_1812930078.webp)
78
GB MagFlux Manual 0812
Electromagnetic Flow Meter
Settings and Limits for Batch Counters
Batch counter units
Available units are
l, hl, kl, m
3
, ft
3
, gal and MG.
Start, stop or pause with Digital Input
The manual and the adaptive batch counters can be started, stopped
or paused via the digital input (DI)
On-time
The pulse length of the opto digital output (DO 1) is adjustable from 1
ms to 10 secs.
The pulse length of the mechanical digital relay (DO 2) is adjustable
from 100 ms to 10 secs.
Volume between pulses
Select a volume between pulses as listed in the table overleaf.
The relays are limited to a minimum and a maximum of pulses pr. hour
depending on the 20 mA scale and the on-time of the relay in milli-
seconds.