'12 • SRK-T-122
7. CAPACITY TABLE
Model SRK90CL-BN
Cool Mode
ISC11186
Air flow
Outdoor
air temp.
Indoor air temp
21˚CDB
23˚CDB
26˚CDB
27˚CDB
28˚CDB
31˚CDB
33˚CDB
14˚CWB
16˚CWB
18˚CWB
19˚CWB
20˚CWB
22˚CWB
24˚CWB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
Hi
20.5
(m3/min)
20
8.46
6.43
8.91
6.35
9.38
6.61
9.60
6.55
9.79
6.46
10.18
6.66
10.51
6.46
22
8.27
6.33
8.72
6.25
9.21
6.53
9.44
6.48
9.64
6.40
10.04
6.60
10.38
6.41
24
8.07
6.22
8.52
6.16
9.04
6.45
9.28
6.40
9.47
6.33
9.89
6.54
10.24
6.36
26
7.87
6.12
8.32
6.06
8.86
6.37
9.11
6.32
9.31
6.26
9.74
6.49
10.10
6.29
28
7.66
6.00
8.11
5.95
8.68
6.28
8.94
6.26
9.14
6.19
9.59
6.40
9.95
6.24
30
7.45
5.90
7.90
5.84
8.49
6.19
8.76
6.16
8.96
6.09
9.43
6.34
9.80
6.19
32
7.23
5.79
7.68
5.75
8.30
6.11
8.58
6.09
8.78
6.03
9.26
6.29
9.64
6.14
34
7.01
5.68
7.46
5.64
8.10
6.03
8.39
6.01
8.59
5.95
9.09
6.23
9.48
6.09
35
6.89
5.62
7.34
5.59
8.00
5.99
8.30
5.98
8.50
5.92
9.01
6.20
9.39
6.07
36
6.78
5.57
7.23
5.54
7.89
5.93
8.20
5.94
8.40
5.88
8.92
6.17
9.31
6.03
38
6.55
5.45
6.99
5.43
7.69
5.85
8.01
5.85
8.20
5.80
8.74
6.10
9.13
5.97
39
6.43
5.40
6.87
5.37
7.58
5.80
7.91
5.81
8.10
5.76
8.65
6.07
9.04
5.95
Содержание SRK90CL-BN
Страница 7: ...12 SRK T 122 Unit mm 60 17 3 150 3 Remote controller a Wireless remote controller...
Страница 33: ...32 12 SRK T 122 4 Troubleshooting procedure If the air conditioner runs NO YES 33...
Страница 51: ...50 12 SRK T 122 11 3 Super link E board SC ADNA E F SL2NA E and SL3N AE BE to control...
Страница 52: ...51 12 SRK T 122...