12
-
Unit indication section
Models All models
4.2 Back-up switch
When the remote controller batteries become weak, or if the remote controller is lost or malfunctioning, this switch may be used to turn
the unit on and off.
(a)
Operation
Push the switch once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by sensor),
whether to go into the cooling, thermal dry or heating modes.
Function
Room temperature
Operation mode
setting
Fan speed
Flap
Timer switch
Cooling
About 25ºC
Thermal dry
About 25ºC
Auto
Auto
Continuous
Heating
About 26ºC
ON/OFF button
ECONOMY light (orange)
Illuminates during ECONOMY operation.
TIMER light (yellow)
Illuminates during TIMER operation.
HI POWER light (green)
Illuminates during HI POWER operation.
RUN (HOT KEEP) light (green)
•
Illuminates during operation.
•
Flashes at air flow stop due to the ‘HOT KEEP’.
4.3 Power blackout auto restart function
(1)
Power blackout auto restart function is a function that records the operational status of the air-conditioner immediately prior to it
being switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.
(2)
The following settings will be cancelled:
(a)
Timer settings
(b)
High-power operations
Notes (1) The power blackout auto restart function is set at on when the air-conditioner is shipped from the
factory. Consult with your dealer if this function needs to be switched off.
(2) When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.
(3) If the jumper wire (J7) “REMOTE/AUTORESTART” is cut, auto restart is disabled. (See the diagram at
right)