17
-
(3)
Detail of control in each mode (Pattern)
(a)
Fuzzy operation
During the fuzzy operation, the air flow and the inverter speed are controlled by calculating the difference between the room
temperature setting correction temperature and the suction air temperature.
(b)
Cooling thermostat operation
(i)
Operating conditions
During the cooling fuzzy operation or when the speed obtained by the fuzzy calculation is less than -24 rps.
(ii)
Detail of operation
(2)
Air flow selection
(a)
Speed of inverter changes within the range of selected air flow.
(b)
When any protective function actuates, the operation is performed in the mode corresponding to the function.
(c)
Outdoor blower is operated in accordance with the inverter command speed.
(c)
Cooling “HI POWER” operation
(HI POWER button on remote controller: ON)
The unit is operated continuously for 15 minutes regardless of the setting temperature.
(i)
Detail of operation
Model
SRK25, 35ZD-S
SRK50ZD-S
Item
Inverter speed
0 rps [Comp. stopped]
10rps [10sec.]
→
0rps [Comp. stopped]
Indoor fan
Corresponds to fan speed switch.
Outdoor fan
Stop
2nd speed [1min.]
→
stop
Notes (1) Protective functions will actuate with priority even during the “HI POWER” operation.
(2) Room temperature is not adjusted during the “HI POWER” operation
4.8 Outline of dehumidifying operation
(1)
After operating the indoor blower for 20 seconds from immediately after the start of operation, the indoor temperature is checked
and, based on the result of check, the cooling oriented dehumidifying or heating oriented dehumidifying is selected.
Heating oriented dehumidifying
Cooling oriented dehumidifying
Low
–3
High
Room temperature - Setting temperature (deg)
Cooling or heating oriented dehumidifying is selected again one hour after the first selection of the cooling or heating oriented
dehumidifying.
Model
SRK25ZD-S
SRK35ZD-S
SRK50ZD-S
Item
Inverter speed
62
70
84
Indoor fan
7th speed
7th speed
Outdoor fan
4th speed
2nd speed
Model
SRK25ZD-S
SRK35ZD-S
SRK50ZD-S
Air flow selection
Inverter command speed
20~62rps
20~70rps
15~84rps
Air flow
Depends on inverter command speed.
Inverter command speed
20~62rps
20~70rps
15~84rps
Air flow
7th speed fixed
5th~7th speed
Inverter command speed
20~52rps
20~58rps
15~60rps
Air flow
5th speed fixed
3rd~5th speed
Inverter command speed
20~34rps
20~38rps
15~30rps
Air flow
2nd speed fixed
Auto
HI
MED
LO