'14•SRK-T-164
– 37 –
Insulation of connecting portion
①
Cover the connection portion of the refrigerant piping with the
pipe cover and seal them.
If neglecting to do so, moisture occurs on the piping and water will
drip out.
②
Finishing and fixing
ⓐ
Tie up the piping with wrapping tape, and shape it so that it conforms
to which the pipe is attached.
ⓑ
Fix them with clamps as right figure.
Vinyl tape
To cover the connecting portion with insulation
materials, cut upper portion and then seal it
with insulation materials.
Cover the exterior portion with cov-
ering tape and shape the piping so it
will match the contours of the route
that the piping to take. Also fix the
wiring and pipings to the wall with
clamps.
Insulation
Refrigerant piping
Electrical wiring
Covering tape
Drain hose
Tapping screw
♦
Additional refrigerant charge
Air purge
Additional refrigerant
Less than 15m : Not required
More than 15m : 20g/m
How to relocate or dispose of the unit
•
In order to protect the environment, be sure to pump down (recovery
of refrigerant).
•
Pump down is the method of recovering refrigerant from the indoor
unit to the outdoor unit when the pipes are removed from the unit.
<How to pump down>
①
Connect charge hose to check joint.
②
Liquid side : Close the liquid valve with hexagon wrench key.
Gas side : Fully open the gas valve.
Carry out cooling operation. (If indoor temperature is low, operate
forced cooling operation.)
③
After low pressure gauge become 0.01MPa, close the gas valve then
stop cooling operation.
•
Forced cooling operation
Turn on a power supply again after a while after turn off a power supply.
Then press continually the ON/OFF button 5 seconds or more.
21 Series
26 Series
Unit ON/OFF button
Unit ON/OFF button
Securely tighten the operation valve cap and the check joint blind nut after
adjustment.
Operation valve size
(mm)
Operation valve cap
tightening torque (N·m)
Check joint blind nut
tightening torque (N·m)
φ
6.35 (1/4")
20 ~ 30
10 ~ 12
φ
9.52 (3/8")
φ
12.7 (1/2")
25 ~ 35
φ
15.88 (5/8")
30 ~ 40
Compound pressure gauge
Operation valve cap
Operation valve
(three-way valve)
Operation valve
cap
-0.1MPa
(-76cmHg)
Handle Lo
Pressure gauge
Handle Hi
Charge hose
(Designed specifically for R410A)
Vacuum pump adapter
(Anti-reverse flow type)
(Designed specifically for R410A)
Vacuum pump
Charge hose (Designed specifically for R410A)
Check joint
Operation valve
(two-way valve)
Gauge manifold
(Designed specifically for
R410A)
Tighten all flare nuts in the pipings both indoor and
①
outside wall so as not to cause leak.
Connect operation valve, charge hose, manifold valve
②
and vacuum pump as is illustrated right.
Open manifold valve handle Lo to its full width, and
③
perform vacuum or evacuation.
Continue the vacuum or evacuation operation for
15 minutes or more and check to see that the vacuum
gauge reads -0.1MPa.
After completing vacuum operation, close the Lo handle
④
and stop operation of the vacuum pump.
After completing vacuum operation, fully open
⑤
operation valve (Both gas and liquid sides) with
hexagon headed wrench.
Check for possible leakage of gas in the connection
⑥
parts of both indoor and outdoor.
Since the system uses check joints differing in diameter
•
from those found on the conventional models, a charge
hose (for R22) presently in use is not applicable. Please
use one designed specifically for R410A.
Please use an anti-reverse flow type vacuum pump adapter
•
so as to prevent vacuum pump oil from running back into
the system. Oil running back into an air-conditioning
system may cause the refrigerant cycle to break down.
RMA012A076A_En.indb 37
22-Jan-14 09:00:41
Содержание SRK19CNS-S
Страница 2: ......
Страница 3: ...14 SRK T 164 TECHNICAL MANUAL...
Страница 12: ...10 14 SRK T 164 3 Wireless remote control Unit mm 60 17 3 150 Unit mm 60 17 3 150...
Страница 40: ...38 14 SRK T 164 4 Troubleshooting procedure If the air conditioner runs NO YES 39...
Страница 48: ...46 14 SRK T 164...
Страница 53: ...51 14 SRK T 164 MEMO...
Страница 59: ...57 14 SRK T 164 MEMO...
Страница 62: ...60 14 SRK T 164 CRBE0393 14 2 5 3 6 7 8 9 11 13 4 17 12 15 15 16 15 15 10 1 18 PANEL FAN ASSY...
Страница 66: ...64 14 SRK T 164 CRBE0395 11 7 1 2 8 12 20 4 20 13 10 6 5 3 13 9 13 15 14 16 17 21 18 19 20 PANEL FAN ASSY...