'14•SRK-T-164
– 30 –
①
A place where good air circulation can be obtained and where rain,
snow or sunshine will not directly strike the unit.
②
A place where discharged hot air or unit’s operating sound will not be
a nuisance to the neighborhood.
③
A place where servicing space can be secured.
④
A place where vibration will not be enlarged.
*Avoid installing in the following places.
s
A place near the bedroom and the like, so that the operation noise
will cause no trouble.
s
A place where there is possibility of flammable gas leakage.
s
A place exposed to strong wind.
s
In a salt-laden atmosphere or a place where the generation of oil
mist, vapor or fume is expected.
⑤
Blowing out port and suction port on the back side of the unit can be
installed at a distance of 10cm from walls.
In case the barrier is 1.2m or above in height, or is overhead, the
sufficient space between the unit and wall shall be secured.
⑥
When the unit is installed, the space of the following dimension and
above shall be secured.
OUTDOOR UNIT
Note (1) If the wall is higher than 1.2 m or a ceiling
is present, distances larger than indicated in
the above table must be provided.
Selection of installation location
①
Where there is no obstructions to the air flow and where the cooled
air can be evenly distributed.
②
A solid place where the unit or the wall will not vibrate.
③
A place where there will be enough space for servicing. (Where
space mentioned right can be secured)
④
Where wiring and the piping work will be easy to conduct.
⑤
The place where receiving part is not exposed to the direct rays of
the sun or the strong rays of the street lighting.
⑥
A place where it can be easily drained.
⑦
A place separated at least 1m away from the television or the radio.
(To prevent interfence to images and sounds.)
⑧
A place that home appliance and household goods, etc. aren’t below
unit.
INDOOR UNIT
10 cm
5 cm
10 cm
Left
side
60 cm MIN
Air intake
10 cm MIN
10 cm
MIN
Air outlet
Air
intake
No obstacles
(Service space
for electrical
parts)
Right
side
)
(
Standard accessories
(Installation kit)
Accessories for indoor unit
Q'ty
①
Installation board
(Attached to the rear of the indoor unit)
1
②
Wireless remote control
1
③
Remote control holder
④
Tapping screws
(for installation board 4dia. by 25mm)
5 (21)
10 (26)
⑤
Wood screw
(for remote control switch holder 3.5dia. by 16mm)
2
⑥
Baterry [R03 (AAA, Micro) 1.5V]
2
⑦
Air-cleaning fi
2
s
r
e
tl
⑧
Filter holders
(Attached to the front panel of the indoor unit)
2
Option parts
Q'ty
ⓐ
Sealing plate
1
ⓑ
Sleeve
1
ⓒ
Inclination plate
1
ⓓ
Putty
1
ⓔ
Drain hose (extention hose)
1
ⓕ
Piping cover
(for insulation of connection piping)
1
Necessary tools for the installation work
1
Plus headed driver (Phillips screwdriver)
2
Knife
3
Saw
4
Tape measure
5
Hammer
6
Spanner wrench
7
Torque wrench
(
14.0 ~ 82.0N · m
(1.4 ~ 8.2kgf · m)
)
8
Hole core drill (65mm in diameter)
9
Wrench key (Hexagon) [4m/m]
10
Vacuum pump
11
Vacuum pump adapter
(Anti-reverse flow type)
(
Designed specifically
for R410A
)
12
Gauge manifold
(
Designed specifically
for R410A
)
13
Change hose
(
Designed specifically
for R410A
)
14
Flaring tool set
(
Designed specifically
for R410A
)
15
Gas leak detector
(
Designed specifically
for R410A
)
16
Gauge for projection adjustment (Used when flare is
made by using conventional flare tool)
17
Pipe bender
RMA012A076A_En.indb 30
22-Jan-14 09:00:39
1
Содержание SRK19CNS-S
Страница 2: ......
Страница 3: ...14 SRK T 164 TECHNICAL MANUAL...
Страница 12: ...10 14 SRK T 164 3 Wireless remote control Unit mm 60 17 3 150 Unit mm 60 17 3 150...
Страница 40: ...38 14 SRK T 164 4 Troubleshooting procedure If the air conditioner runs NO YES 39...
Страница 48: ...46 14 SRK T 164...
Страница 53: ...51 14 SRK T 164 MEMO...
Страница 59: ...57 14 SRK T 164 MEMO...
Страница 62: ...60 14 SRK T 164 CRBE0393 14 2 5 3 6 7 8 9 11 13 4 17 12 15 15 16 15 15 10 1 18 PANEL FAN ASSY...
Страница 66: ...64 14 SRK T 164 CRBE0395 11 7 1 2 8 12 20 4 20 13 10 6 5 3 13 9 13 15 14 16 17 21 18 19 20 PANEL FAN ASSY...