Ventilation display

Displayed during ventilation operation
 

☞ 

See page 12

Weekly timer display

Displays the settings of the 
weekly timer.

Operation setting display area

Displays setting temperature, airflow 
volume, operation mode and operation 
message.

Operation/check indicator light

During operation: Lit in green
In case of error: Flashing in red

Operation/stop button

This button is used to operate and stop 
the air conditioning system.
Press the button once to operate 
the system and press it twice 
to stop the system.

MODE button

This button is used to change the 
operation mode.

FAN SPEED button

This button is used to set the airflow 
volume.

VENT button

This button is used to operate external 
ventilator.  

☞ 

See page 12

LOUVER button

This button is used to operate/stop the 
swing louver.  

☞ 

See page 11

SET button

•This 

button is used to fix the setting. 

•This 

button is used to set the silent mode.  

☞ 

See page 5 to 12

RESET button

•If y

ou press this button while making settings, 

you can go back to the previous operation.  

☞ 

See page 5 to 12

•This 

button is also used to reset the “FILTER CLEANING” display.

(Press it after cleaning the air filter)

Central control display
Displayed when the air conditioning system is 
controlled by centralized remote control.

Timer operation display

Displays the timer operation setting.

Temperature setting buttons

These buttons are used to set the 
temperature of the room.

Timer button

This button is used to set 
the timer mode. 

☞ 

See page 5

Timer setting buttons

These buttons are used to set 
the timer mode and the time.

☞ 

See page 5 to 12

E.S.P. button

This button is only used by service 
engineers for installation purposes.

AIR CON No. button

•Displa

y the indoor unit number connected to this 

  remote control.

•This b

utton is used for indoor unit address setting.

CHECK button 

This button is only used by service engineers 
for installation purposes.

TEST button

This button is used during test operation.

 

NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS 

(Wired remote control)

Wired remote control

•  The figure below shows the remote control with the cover opened. Note that the items in the liquid 

crystal display (LCD) area are shown for explanation purpose.

Pull the cover downwards to open.

HOW TO USE< WIRED REMOTE CONTROL >

 PrecAUtionS For WASte diSPoSAl

Your Air Conditioning product may be marked with this symbol. It means that waste electrical and 
electronic equipment (WEEE as in directive 2012/19/EU) should not be mixed with general household 
waste. Air conditioners should be treated at an authorized treatment facility for re-use, recycling and 
recovery and not be disposed of in the municipal waste stream. Please contact the installer or local 
authority for more information. 

  

PRECAUTIONS FOR RELOCATION 
OR REPAIRING

 cAUtion

Never perform any 

modification. Contact 

your dealer for repairing.

Improper repairing may lead to 

water leakage, electric shock 

or fire. Normally the refrigerant 

does not leak. But if it leaks 

and contacts fire such as 

fan heater, space heater or 

cooking heater, it may produce 

toxic chemicals. When repairing 

refrigerant leakage, determine 

the service with the service 

staff that the repair has been 

finished without fault.

If it is required to 

relocation and reinstall 

the unit, consult your dealer 

or a specialist.

Improper installation of air 

conditioning unit may cause 

water leakage, electric shock 

and/or fire.

Before repairing or 

checking indoor unit, be 

sure to turn off “Indoor unit 

power supply breaker”.

It can result in electric shock or 

injury due to rotation of indoor 

unit fan if you perform check 

or repair with the “Indoor unit 

power supply breaker” turned 

on.

Place the panels removed 

for repairing or checking 

on the stable spot.

Otherwise, dropping or falling 

may lead to injury.

Содержание RC-E5

Страница 1: ... συμβατότητας EMC και την οδηγία LV 2006 95 ΕΚ Tο οήμα CE ισχύει μόνον σε περιοχές όπου η τροφοδοσία είναι 50 Hz Ceiling cassette 4 way FDT Ceiling cassette 4 way Compact 600 600mm FDTC Duct connected High static pressure FDU FDUS Duct connected Middle static pressure FDUM Ceiling Suspended FDE Floor Standing FDF USER S MANUAL ENGLISH MANUEL DE L UTILISATEUR ANWENDERHANDBUCH DEUTSCH ISTRUZIONI PER...

Страница 2: ... BUTTON OPERATION 18 INSTALLATION RELOCATION AND INSPECTION MAINTENANCE 18 OPERATION RANGE 18 MAINTENANCE AND INSPECTION GUIDELINE OF MAIN PARTS OF PACKAGED AIR CONDITIONER 19 INSTALLATION PRECAUTIONS DANGER Make sure to have the installation done by your dealer or a specialist If you install by yourself and the unit is not properly installed water leakage electric shock fire and injuries caused b...

Страница 3: ... But if it leaks and contacts fire such as fan heater space heater or cooking heater it may produce toxic chemicals Do not insert fingers or sticks even if air blower does not operate It may suddenly operate and cause injuries OPERATION PRECAUTIONS DANGER This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of e...

Страница 4: ...y lead to injuries Do not place any other electric appliances or household goods below or around the air conditioner Dripping from the unit may lead to failure or contamination Do not touch the aluminum fin Otherwise it may lead to injuries Do not clean the inside of the indoor unit by yourself Make sure to consult your dealer or user inquiry counter specified by our company If you select incorrec...

Страница 5: ...t address setting CHECK button This button is only used by service engineers for installation purposes TEST button This button is used during test operation NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS Wired remote control Wired remote control The figure below shows the remote control with the cover opened Note that the items in the liquid crystal display LCD area are shown for explanation purpos...

Страница 6: ...s prohibited When you start to operate the unit for the first time after turning the power supply on the default settings are listed below You can change them as you like Central control Turned off Operation changeover With auto mode auto cooling Without auto mode cooling Set temperature 23 C Fan speed Louver position Horizontal ATTENTION 1 Press button The unit starts operating 2 Press MODE butto...

Страница 7: ...r entering the timer mode the timer mode ends and the display returns to the original one If you press button while timer mode is under setting timer mode is canceled and the display will return to the original one If you do not press any button for several minutes after entering the timer mode the timer mode ends and the display returns to the original one ATTENTION After a certain period of time...

Страница 8: ...splay returns to the original one NOTICE EXAMPLE Number 1 Number 2 Number 3 Number 4 Four operations can be set with only ON timer or only OFF timer HOW TO PERFORM THE TIMER OPERATION WIRED REMOTE CONTROL 1 Press TIMER button 2 Press button for three times 3 Press SET button EXAMPLE flashes lights 4 Press or button Set the preferred time to start the operation Set Hour If you press or button for a...

Страница 9: ... timer mode the timer mode ends and the display returns to the original one NOTICE HOW TO PERFORM THE TIMER OPERATION WIRED REMOTE CONTROL 5 Press SET button mark next to a number lights or is displayed The settings so far are effective and the display changes as shown on the left 6 Press or button Press button and is displayed Press button and is displayed Select either of the above two Press the...

Страница 10: ...to temporarily disable each day s timer setting by using the Holiday Setting When the Holiday Setting is cancelled the timer setting is enabled again 1 In the Weekly timer mode select and set See Selection of Weekly timer mode step 1 to 5 on page 7 is displayed in the display area is flashing is displayed 2 Press or button Move the mark displayed above the days of week to the day which you want to...

Страница 11: ...ay Canceling Silent Mode Setting Select in step 2 press SET button and silent setting is canceled ending the silent mode is displayed SILENT MODE Silent Mode Setting If you press button while timer mode is under setting timer mode is canceled and the display will return to the original one Note that the setting which has not been completed is canceled HOW TO PERFORM THE TIMER OPERATION WIRED REMOT...

Страница 12: ...louver No The louver No to be set is confirmed and the display shows the upper limit of the movable range EXAMPLE If No 1 louver is selected current upper limit position 6 Press or button selection of upper limit position Select the upper limit of louver movable range position 1 is the most horizontal and position 6 is the most downwards position is to return to the factory setting If you need to ...

Страница 13: ... The cooling heating capacity will get reduced Moreover it leads to waste of electricity and larger operation noise It may cause failure Dew may form and drop during cooling Do not block the inlet and outlet grilles of the indoor and outdoor units Excessive load to the unit may cause failure Keep moderate room temperature Too much cooling or heating is not good for your health It will also waste t...

Страница 14: ...icates set temperature FILTER display Indicates for two seconds when FILTER button is pressed OFF TIMER display Indicates when OFF TIMER is set See page 14 OPERATION MODE select button Every time this button is pressed displays switch as below AUTO COOL HEAT FAN DRY ROOM TEMP TIME SETTING button Sets room temperature by pressing or button Sets time when setting the time ACL switch Used to reset th...

Страница 15: ...off the power supply Power is distributed to the crankcase heater even if the compressor is stopped This keeps the compressor warm and prevents failures caused by accumulation of liquid refrigerant The operation of remote control must be performed slowly and steadily HOW TO USE WIRELESS REMOTE CONTROL ATTENTION 4 1 5 3 2 AUTO COOL HEAT DRY FAN Guideline of room temperature setting COOL 26 to 28 C ...

Страница 16: ...form them address No and error code symptom of the trouble air conditioner type and model name etc Press the ON OFF button to stay the air conditioner on the stop mode lights for 0 5 seconds and blinks for 0 5 seconds Timer check indicator lamp WHEN LONG FLASHING LIGHT IS SHED FROM THE TIMER CHECK INDICATOR LAMP YELLOW Clean the filter See page 16 When cumulative running time reaches to 120 hours ...

Страница 17: ...t in the way indicated with arrow mark 4 2 Ensure to insert the holders of the grille into the filter s holes until clicking sounds are heard How to mount the grille 1 Mount the hooks of the grille to the holes on the panel The hooks on the grille can be mounted in all 4 directions 2 Close the grille while pressing the stoppers on the grille 2 places to the OPEN direction Then release the stoppers...

Страница 18: ...ted when the compressor is activated deactivated during operation or when the operation is stopped These are the sounds of the refrigerant flowing through the system Sounds of rustling or gurgling may be heard from a stopped indoor unit These sounds can be heard when the air conditioning system is performing automatic control The supply air from the indoor unit smells bad The supply air from the i...

Страница 19: ... do by yourself Is the system installed in a well ventilated place Are there any obstacles If so it leads to the decrease of the efficiency and the increase of operation noise Avoid the place where cool warm air and operation noise cause problems to your neighbors INSTALLATION LOCATION Normally the efficiency of the air conditioning system will become lower after a while because dirt accumulates i...

Страница 20: ...ega There should be no abnormal sound generation The resistance value should be 1 M or more When a bearing sound is loud replace the bearing When the resistance value is 1 M or less replace the motor 20 000 Hr Bearing Regular lubrication is required Audible inspection There should be no abnormal sound generation Replace parts regularly 15 000 Hr Consumable components Automatic louver motor Insulat...

Страница 21: ...cted 5 years Cleaning object item Due to atmospheric dirt Piping in the unit Sympathetic vibration contact and corrosion of the piping in the unit Sympathetic vibration and contact of capillary tube Visual inspection Visual inspection There should be no abnormal sympathetic vibration sound or corrosion There should be no abnormal sympathetic vibration or contact wear Replace it or readjust the pip...

Страница 22: ...sited foreign matter Retighten it if it is loose Clean with a brush in case of deposited foreign matter adhesion 25 000 Hr Electrical component including boards etc HIC board short circuit check Visual check of dirt adhesion to the board etc Self diagnosis mode appearance check Tester Visual inspection Visual inspection Should be of a specified resistance value There should be no deposited foreign...

Страница 23: ...22 ...

Страница 24: ...Tel 44 20 7025 2750 Fax 44 20 7025 2751 http www mhiae com MITSUBISHI HEAVY INDUSTRIES AIR CONDITIONERS AUSTRALIA PTY LTD 9C Commercial Road Kingsgrove NSW 2208 PO BOX 318 Kingsgrove NSW 1480 Tel 61 2 8571 7977 Fax 61 2 8571 7992 http www mhiaa com au MITSUBISHI HEAVY INDUSTRIES MAHAJAK AIR CONDITIONERS CO LTD 220 Soi Chalongkrung 31 Kwang Lamplatiew Khet Lad Krabang Bangkok 10520 Thailand Tel 66 ...

Отзывы: