5 - 8 5 - 8
MELSEC-Q
5 DETAILS AND SETTING OF FUNCTIONS
Buffer memory address
Item
Read value/Setting value
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8
Accumulating count value 0 to 99999999
8
9
40
41
72
73
104
105
136
137
168
169
200
201
232
233
Carry over detection flag
0: No carry over detection (OFF)
1: Carry over detection (ON)
14 46 78 110 142 174 206 238
Carry over reset request
1: Reset request
(The value automatically turns
to "0" after completion of a
carry over reset.)
15 47 79 111 143 175 207 239
POINT
The carry over detection flag is not cleared until a carry over reset request is given.
Once cleared, the carry over detection flag does not turn ON until the accumulating