PLFY-3
PLFY-P-NCMU-ER4, -NBMU-E2 (November 2015)
© 2015 Mitsubishi Electric US, Inc.
Model
PLFY-P08NCMU-ER4
PLFY-P12NCMU-ER4
PLFY-P15NCMU-ER4
Power source
1-phase 208-230 V 60Hz
Cooling capacity *1
(Nominal)
Btu/h
8,000
12,000
15,000
kW
2.3
3.5
4.4
Power input
kW
0.05
0.06
0.06
Current input
A
0.23
0.28
0.28
Heating capacity *2
(Nominal)
Btu/h
9,000
13,500
17,000
kW
2.6
4.0
5.0
Power input
kW
0.05
0.06
0.06
Current input
A
0.23
0.28
0.28
External finish
Galvanized Steel Sheet
External dimension H x W x D
in.
8-3/16 x 22-7/16 x 22-7/16
8-3/16 x 22-7/16 x 22-7/16
8-3/16 x 22-7/16 x 22-7/16
mm
208 x 570 x 570
208 x 570 x 570
208 x 570 x 570
Net weight
lbs (kg)
34 (15.5)
37 (17)
37 (17)
Decoration
panel
Model
SLP-15AAUW
SLP-15AAUW
SLP-15AAUW
External finish
Munsell No. 6.4Y 8.9/0.4
Dimension
in.
25/32 x 25-19/32 x 25-19/32
25/32 x 25-19/32 x 25-19/32
25/32 x 25-19/32 x 25-19/32
H x W x D
mm
20 x 650 x 650
20 x 650 x 650
20 x 650 x 650
Net Weight
lbs (kg)
7(3)
7(3)
7(3)
Heat exchanger
Cross fin
Fan
Type x Quantity
Turbo fan x 1
Turbo fan x 1
Turbo fan x 1
External
static pressure
in.WG
0.000 (208V)
0.000 (208V)
0.000 (208V)
Pa
0
0
0
in.WG
0.000 (230V)
0.000 (230V)
0.000 (230V)
Pa
0
0
0
Motor type
1-phase induction motor
Driving mechanism
Direct-driven
Airflow rate
(Low-Mid-High)
CFM
280-320-350
320-350-390
320-350-390
m3 / min
8.0-9.0-10.0
9.0-10.0-11.0
9.0-10.0-11.0
L / s
133-150-167
150-167-183
150-167-183
Sound pressure level (Low-Mid-High)
(measured in anechoic room)
dB <A>
29-32-38 (208-230V)
30-34-39 (208-230V)
31-35-40(208-230V)
Insulation material
Polyethylene foam
Air filter
Polypropylene honeycomb fabric
Protection device
Fuse
Refrigerant control device
LEV
Connectable outdoor unit
R410A,R22 CITY MULTI
Diameter of
refrigerant pipe
(O.D.)
Liquid (R410A)
in. (mm)
1/4 (6.35) Flare
1/4 (6.35) Flare
1/4 (6.35) Flare
Gas (R410A)
in. (mm)
1/2 (12.7) Flare
1/2 (12.7) Flare
1/2 (12.7) Flare
Field drain pipe size
in. (mm)
O.D. 1-1/4(32)
O.D. 1-1/4(32)
O.D. 1-1/4(32)
Drain Lift Mechanism
in. (mm)
19-11/16 (500)
19-11/16 (500)
19-11/16 (500)
Drawing
External
RG01N654
Wiring
RG79V389
Refrigerant cycle
-
Standard attachment Document
Accessory
Installation Manual,Installation Book
Drain hose<1-1/4in.(32mm)>
Optional parts
External heater adapter
CN24RELAY-KIT-CM3
CN24RELAY-KIT-CM3
CN24RELAY-KIT-CM3
Decoration panel
SLP-15AAUW
SLP-15AAUW
SLP-15AAUW
Remark
*PLFY-P-NCMU-E should used together with SLP-15AAUW.
Installation
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
Ventilation Air: Providing sufficient ventilation air is an important part of every building design.
ASHRAE standard 62 provides the minimum ventilation air requirements. Also check local
codes.
1. SPECIFICATIONS
Note:
*1 Nominal cooling conditions
*2 Nominal heating conditions
Unit converter
Indoor:
80degF D.B. / 67degF W.B.
(26.7degC D.B. / 19.4degC W.B.)
70degF D.B. (21.1degC D.B.)
kcal/h = kW x 860
BTU/h = kW x 3,412
Outdoor:
95degF D.B. (35degC D.B.)
47degF D.B. / 43degF W.B.
(8.3degC D.B. / 6.1degC W.B.)
cfm = m3/min x 35.31
lbs = kg / 0.4536
Pipe length:
25 ft. (7.6 m)
25 ft. (7.6 m)
*Above specification data is subject to
rounding variation.
Level difference:
0 ft. (0 m)
0 ft. (0 m)
*Due to continuing improvement, above specification may be subject to change without notice.
PLFY-P08NCMU-ER4, PLFY-P12NCMU-ER4, PLFY-P15NCMU-ER4